9.2.16 Test for checking the core probe proper insertion
Temperature cycles are preceeded by a two-phase test to check if the core probe has been properly
inserted.
The second phase will be carried out only if the first one has not been successfully completed.
If the test has been successfully completed the cycle starts otherwise the buzzer will be sounding
for 5 seconds every 60 seconds and a time cycle will start.
►
However to start a temperature cycle press the key
or the key
; : after 1 minute since the
signal warns that test has not been successfully completed without operating a time cycle will start.
9.2.17 Switching-on of the UV light for the sterilization cycle (optional)
Proceed as follows:
►
Make sure the display is in the “ON” mode and the door
is closed i.e. micro input port is not active.
►
Make sure the keyboard is not locked and no procedu-
re is currently under process.
►
Press and release the
(1) key, press and relea-
se the
(2) key, , then press and release the START
/ STOP key (3);
The display will show the remaining time of the UV light switching on and the cell temperature.
►
The UV light is switched on ; the opening of the door, i.e the micro input port is open , causes the
light switching off
9.2.18 Fish Sanification cycle
This Blast Chiller is provided with a specific program for raw fish sanification with adequate tempe-
rature and time. The Fish Sanification program consists of the following three phases:
►
Temperature Freezing with core probe (core probe temperature -20°C)
►
Holding time (core probe temperature -20°C duration: 24 hours)
►
Preservation (cell temperature -22°C unlimited duration)
When a phase is over the system automatically switches to the next step.
To start the cycle proceed as follows: