29
ENGLISH
9.2.19 Defrosting the device
Defrosting is carried out automatically on Trolley blast chiller, only if the evaporator temperature re-
quires it at the end of each chilling or freezing cycle, and every 8 hours during storage cycle.
It is possible to activate a manual defrosting as follows:
►
Make sure the device is “on” and that either a pre-co-
oling or a storage but no chilling or freezing cycle is in
progress.
►
Push and release key
(1), push and release
key
(2), then push and release key
START / STOP (3).
►
Defrosting will be activated only if the evaporator temperature is lower than the set one (+8); if not,
defrosting will not be activated.