44
ENGLISH
C2
0
240
min
3
3
minimum time interval between the switching off of compressor
and the following switching on (3)
C3
0
240
s
0
0
Minimum duration of the compressor switching on
C4
0
240
min
10
10
Duration of the compressor switching off during cell probe error
(code “Pr1”) occurring during preservation; see also the C5 and
C9 parameters
C5
0
240
min
10
10
Duration of the compressor switching on during cell probe error
(code “Pr1”) occurring during preservation after cooling ; see
also the C4 parameter
C6
0
199
°C / °F (1)
80
80
condenser temperature above which the overheated condenser
alarm is activated (code “COH”) (4)
C7
0
199
°C / °F (1)
90
90
condenser temperature above which the blocked compressor
alarm is activated (code “CSd”)
C8
0
15
min
1
1
Block compressor delayed alarm (code “CSd”) (5)
C9
0
240
min
30
30
Duration of the compressor switching on during cell probe error
(code “Pr1”) occurring during preservation after freezing; see
also the C4 parameter
Par.
Min.
Mas.
Unità
Default
Default
Defrosting (6)
d0
0
99
h
8
0
Defrost time interval (7)
0 = defrost with set time and intervals shall never be activated
d1
0
3
- - - -
1
2
Type of defrost
0 = elettric-type (during defrost compressor is switched off, the
defrost output is activated and the evaporator fan is
switched off)
1 = hot gas-type (during defrost the compressor is switched on,
the defrost output is activated and the evaporator fan is
switched off)
2 = air-type (during defrost the compressor is switched off and the
defrost output is activated; the evaporator fan is switched
on independently from the conditions of the door, i.e.
Independently from the status of the micro input door)
3 = air-type with open door (during defrost the compressor is
switched off and the defrost output is activated; the
evaporator fan is switched on provided that the door
is open, i.e. The micro input door is active and the i0
parameter is set to values different from 0)
d2
-99
99
°C / °F (1)
8
8
Temperature of end-of-defrost (evaporator temperature) ; see
also the d3 parameter
d3
0
99
min
10
30
If the P4 parameter is set to 0, duration of defrost
if the P4 parameter is set to 1, maximum duration of defrost; see
also the d2 parameter
0 = defrost will never be activated
d4
0
1
- - - -
0
0
Defrost on cooling and freezing starting
1 = yes
d5
0
99
min
1
1
Delayed defrost at preservation starting
0 = defrost is activated after time set with the d0 parameter has
passed by.
d7
0
15
min
3
3
Duration of dripping (during dripping compressor and evaporator
fan are switched off and the defrost output is deactivated)
d15
0
99
min
0
0
Minimum duration of the compressor switching on upon the
defrost starting needed to start defrost (if the d1 parameter is set
to 1 only) (8)
d16
0
99
min
0
0
Duration of predripping (if the d1 parameter is set to 1 only;
during predripping compressor and evaporator fan are switched
off and the defrost output is active)
Par.
Min.
Mas.
Unità
Default
Default
Temperature alarms (9) (10)
A1
0
99
°C / °F (1)
10
10
cell temperature below which the minimum temperature alarm is
activated (relative to the working setpoint, i.e. “r10 - A1” during
preservation after cooling and “r11 - A1” during preservation after
freezing ; code “AL”); see also the A11 parameter (4)
A2
0
1
- - - -
1
1
Enable minimum temperature alarm (code “AL”)
1 = yes
A4
0
99
°C / °F (1)
10
10
cell temperature above which the maximum temperature
alarm is activated (relative to the working setpoint , i.e. “r10
+ A4” during preservation after cooling and “r11 + A4” during
preservation after freezing ; code “AH”) ; see also the A11
parameter (4)