47
ENGLISH
i9
-1
240
s
5
5
Delayed low pressure alarm signal (code “LP”)
-1 =alarm is not reported
i10
0
1
- - - -
0
0
iType of contact on the compressor thermal protection input
0 =normally open (active input with closed contact)
1 =normally closed (active input with open contact)
i11
-1
240
s
5
5
Delayed compressor thermal protection alarm signal (code“CtH”)
-1 =alarm is not reported
i12
- - - -
- - - -
- - - -
- - - -
- - - -
riservato
Par.
Min.
Mas.
Unità
Default
Default
Digital outputs
u1
0
1
- - - -
1
1
User managed by the K8 output (15)
0 = pump down valve (in this case the u12 parameter is relevant)
1 = alarm output
u5
-99
99
°C / °F (1)
2
2
Cell temperature above which the door resistances are switched
off (4)
u6
1
240
min
20
20
Duration of the UV light switching on for each sterilization cycle
u7
-99
199
°C / °F (1)
40
40
End-of-heating temperature of core probe (temperature taken by
core probe); see also the u8 parameter
u8
1
240
min
2
2
Maximum duration of core probe heating; see also the u7
parameter
u9
0
1
- - - -
1
1
Core probe heating when door is open, i.e. Activation of the micro
input port occurring after the interruption of a cooling and
preservation cycle or after a freezing and preservation
cycle during preservation
1 = yes
u11
0
1
- - - -
1
1
User managed by the K7 output (15)
0 =cell light (in this case the FREEZING key and the i0
parameter are relevant)
1 =UV light (in this case the FREEZING key and the u6
parameter are relevant)
u12
0
999
s
10
10
Delayed compressor switching off since the pump down valve
deactivation (pump down is switching off) (16)
Par.
Min.
Mas.
Unità
Default
Default
Serial communication (serial port RS-485-type with
communication protocol MODBUS)
L0
- - - -
- - - -
- - - -
- - - -
- - - -
Reserved
L1
1
240
min
15
15
Data recording intervals during cooling and freezing
L2
1
240
min
60
60
Data recordig intervals during preservation
LA
1
247
- - - -
247
247
Device address
Lb
0
3
- - - -
2
2
baud rate
0 = 2.400 baud
1 = 4.800 baud
2 = 9.600 baud
3 = 19.200 baud
LP
0
2
- - - -
2
2
parity
0 = none (no parity)
1 = odd
2 = even
Par.
Min.
Mas.
Unità
Default
Default
Various
E8
0
2
- - - -
0
0
“keyboard block” function activation mode
0 = function not enabled
1 = manual with permanent effect (to block keyboard first make
sure no procedure is currently under process then press
and release the ON / STAND-BY key, then press and
release the highest interactive key on the left; to unblock
keyboard repeat the above procedure)
2 = automatic with temporary effect (after 60 second keyboard is
automatically blocked ; to unblock keyboard, first make
sure that no procedure is currently under process, then
press and release the ON / STAND-BY key then press
and release the highest interactive key on the left)
E9
0
1
- - - -
0
0
View of splash screen during the passage from the “off” to the
“STAND-BY” mode and on power supply reset
1 = yes