41
ENGLISH
HARD LED
On when a hard cycle is selected and you are
viewing the cell setpoint in the first phase, flashing
if you are viewing the setpoint of the second
phase.
On if the first phase of a hard cycle is in progress,
flashing during the execution of the second phase
SOFT BLAST CHILLING LED
On if a positive blast chilling cycle is selected
9.2 INSTRUCTIONS FOR USE
9.2.1 Start up
Before starting up the blast chiller, make sure that the electrical connection and the connection have
been made as indicated in Chapter 15.
When the card is powered, run a lamp-test by turning on all LEDs and displays for five seconds, after
which it will return to the same state it was in before it was powered down.
If, before the power down, there was a cycle in progress, this will be resumed from the point at which
it was interrupted and the display DIS1 will display the flashing label “PF” to indicate that there was
a power failure. If prior to the power failure there was no cycle in progress, the display DIS1 shows
the temperature of the cell probe, while the display DIS2 shows three dashes, in this case the card
is in STANDBY, you can select a cycle and execute it.
With card in OFF :
the display DIS1 displays the label "OFF" while the DIS2 display and all LEDs are off.
►
pressing the ON/OFF button
puts the card in
STANDBY.
►
press continuously for five seconds on the HACCP button
allows you to display
the list of alarms
present in the history.
►
press continuously for five seconds on the TIME button
allows you to enable
the setting of the date
and time.
With card in STANDBY:
►
Pressing the buttons: BLAST CHILLING
or HARD
, TIME FREEZING
,
FREEZING TIME
allows you to select one of these cycles.
►
Pressing the STERILIZATION button
allows you to start a
sterilization cycle.