7700 MultiFrame Manual 

7707VR-8 8 Channel SDI Fiber Receiver 

 Revision 

1.4 

7707VR-8-13 

6.2. 

VistaLINK

®

 MONITORED PARAMETERS 

The following parameters can be remotely monitored through the 

Vista

LINK

® 

interface. 

 

Parameter Description 

Video Present 

1 to 8

 

Indicates the presence of a valid video fiber input signal. 

Video Error 

1 to 8

 

Indicates the presence of errors on a video fiber input signal. 

Video Standard 

1 to 8

 

Indicated the detected video standard. 

Video EDH Present 

1 to 8

 

Indicates the presence of EDH Error Detection packets in video 
fiber inputs. 

Video EDH Error 

1 to 8

 

Indicates EDH Errors in Full Field, Active Picture or ANC Data 
Checksums. 

Fiber Link Present 

Indicates a valid fiber link data stream at fiber input. 

Fiber Link Error 

Indicates errors on valid fiber link input. 

Optical Power Alarm 

Indicates Optical Power at fiber input has dropped below a 
configurable threshold. 

Optical Power 

Indicates optical power level at fiber input. 

Table 6-1: VistaLINK

®

 Monitored Parameters 

 

6.3. 

VistaLINK

®

 CONTROLLED PARAMETERS 

The following parameters can be remotely controlled through the 

Vista

LINK

® 

interface. 

 

Parameter Description 

Video Output Standard on Loss 
1 to 8 

Selects an Output Standard to be generated on loss of Fiber Link.  
This value auto-updates to match the current valid input standard 
when applied. 

EDH Insertion 1 to 8 

Enables recalculated EDH packets to be inserted into video 
stream, with updated error flags. 

Video Signal Block 1 to 8 

Allows the User to Block specific video paths.  Blocked outputs will 
flip to generated sources. 

Passcode Set 

Setup the Password used to access the Video Blocking features. 

Optical Alarm Threshold 

Set the optical power level that trips an alarm if the fiber signal 
degrades. 

Table 6-2: VistaLINK

®

 Controlled Parameters 

Summary of Contents for 7707VR-8

Page 1: ...7 4 2 2 Setting the Video Standard on Loss of Signal 7 4 2 3 Displaying the Optical Power 7 4 2 4 Signal BLOCK Configuration 7 4 2 5 Setting the Orientation of the Text on the Card Edge Display 8 4 2...

Page 2: ...Rear Panel 2 Figure 4 1 Location of Status Indicators and Controls 5 Figure 4 2 Display Menu Structure 6 Figure 5 1 Location of Status Indicators and Jumpers Bottom board A 9 Figure 5 2 Location of St...

Page 3: ...use thereof Any representations in this document concerning performance of Evertz products are for informational use only and are not warranties of future performance either expressed or implied The...

Page 4: ...with a short fiber optic cable The 7707VT 8 DWDM card produce 7dBm of power which will damage the receiver if connected directly Do not hook up the 7707VT 8 cards that output more than 7dBm of power s...

Page 5: ...Mb s SDI DVBASI or SDTi video signals Signal transport over fiber uninterrupted by loss of any input video feed Transparently passes embedded AES or any other data in the horizontal or vertical ancill...

Page 6: ...e and inserting the module into the frame see section 3 of the 7700FR chapter Figure 2 1 7707VR 8 Rear Panel SDI OUTPUT Eight BNC outputs for eight independent reclocked serial digital component video...

Page 7: ...iber Always keep dust caps on optical fiber connectors when not connected and always remember to properly clean the optical end face of a connector before making a connection The transmission characte...

Page 8: ...r of Outputs 8 independent SDI SDTi or DVB ASI 270Mb s signals Connector 1 BNC per IEC 61169 8 Annex A Signal Level 800mV nominal DC Offset 0V 0 5V Rise and Fall Time 900ps nominal Overshoot 10 of amp...

Page 9: ...in board this Red LED indicates poor module status and will be ON during the absence of a valid fiber link input signal or if a local input power fault exists i e a blown fuse On the 7707VR 8B sub boa...

Page 10: ...n either direction The parameter values are changed as you cycle through the list When you have stopped at the desired value depress the pushbutton This will return to the parameter select menu item y...

Page 11: ...are detected CH1 CH8 OSTD N270 P270 ASI OFF N270 SMPTE 259M C 270 Mb s 4 2 2 Component 525 line 4 3 P270 SMPTE 259M C 270 Mb s 4 2 2 Component 625 line 4 3 ASI DVB ASI OFF Signal Generator off 4 2 3 D...

Page 12: ...SP display enables the user to set a horizontal or vertical orientation for the card edge display messages After one second the display will show a message indicating the current orientation of the di...

Page 13: ...re used to preset various operating modes Figure 5 1 and Figure 5 2 show the locations of the jumpers on the bottom and top board respectively FRAME STATUS MODULE OK LOCAL FAULT RUN UPGRADE J7 SERIAL...

Page 14: ...to the same state FRAME STATUS To monitor faults on this module with the frame status indicators on the Power Supply FRAME STATUS LED s and on the Frame s Fault Tally output install this jumper in th...

Page 15: ...e frame Run the upgrade as described in the Upgrading Firmware section in the front of this manual binder Once the upgrade is complete remove the module from the frame move the UPGRADE jumper into the...

Page 16: ...hat the configuration has been carried out There are 3 components of SNMP 1 An SNMP manager also known as a Network Management System NMS is a computer running special software that communicates with...

Page 17: ...ut Optical Power Alarm Indicates Optical Power at fiber input has dropped below a configurable threshold Optical Power Indicates optical power level at fiber input Table 6 1 VistaLINK Monitored Parame...

Page 18: ...7700 MultiFrame Manual 7707VR 8 8 Channel SDI Fiber Receiver 7707VR 8 14 Revision 1 4 This page left intentionally blank...

Reviews: