background image

indicated below in ID code clearing section. 

 

Ú

 

Up to 12 ID codes can be learned.  The Module’s LED will flash rapidly as 
rejection if the 13

th

 ID code is entered. 

 

Clearing the ID Code 

 
(1)  Press the button for 3 seconds until the LED flashes rapidly.    A 30-second 

countdown will start. 

 
(2)  Press the button again more than 6 seconds within 30-second countdown, the 

preset ID code will be cleared. 

 

Operation 

 

z

 

Toggle the On/Off button for On or Off. Turn on the button of which LED will be 
on and the incandescent lamps/appliances controlled by the Module will be on, 
while pressing the button again will turn off the incandescent 
lamps/appliances and its LED will be off. 

 

z

 

When setting to On, the Module will initiate wattage detection function. Upon 
detecting overload condition, the Module will be switched to Off, the On/Off 
button will be disabled and the LED will flash rapidly for 30 seconds. Reset the 
Module by unplugging and re-connecting the plug to the electrical outlet 

 

Troubleshooting

 

 

 

Symptom 

Cause of Failure 

Recommendation 

The module not working and 
LED off 

1.  The module is not 

connected to the mains 
properly 

2.  The module is out of 

order 

1.  Check if wire connection 

is correct 

2. Don’t open up the module 

and send it for repair. 

The module’s LED working, but 
cannot control the ON/OFF 
Switch of the incandescent lamp
connected to the module 

Check if the switch of 
incandescent lamp 
connected to the module 
has its on/off switch 

Set the On/Off switch of the 
connected incandescent lamp 
to ON 

 
Specification 

 

Operating Voltage 

120V/60Hz 

Maximum Load 

1400W 

Range 

Up to 100 meter line of sight 

Frequency Range 

923.00 MHz 

** Specifications are subject to change and improvement without notice.

   

Compatibility 

 

The following transceivers (sold separately) can control THIS module: 

923.00MHz 

     

           

             

               

     

Transmitter   USB Dongle  Flood Detector  IR Beam Detector   Temperature &     Illumination 

                                                                                                                      Humidity Detector        Sensor         

 (AC124)      (SA804)      (ST802)         (ST803)           (ST804)          (ST805)     

IMPORTANT! To avoid poor compatibility with devices of other brands, purchase 

only Everspring UNet devices to ensure best compatibility is strongly 

recommended.

 

 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules.    These limits are designed to 
provide reasonable protection against harmful interference in a residential 
installation.  This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications.  However, there is no guarantee 
that interference will not occur in a particular installation.    If this equipment does 
cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one of the following measures: 
 

Reorient or relocate the receiving antenna. 

-   

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 