background image

4.  To manually turn ON the Module, press and release the 

On/Off  button.  The  LED  will  turn  ON,  and  the  load 
plugged into the Module will also turn ON. 

 
5.  To  manually  turn  OFF  the  Module,  simply  press  and 

release  the  On/Off  button.  The  LED  will  turn  OFF  and 
the load plugged into the Module will also turn OFF. 

 
 
Programming 

 

Z-Wave

TM

 Group Support 

 

The  unit  supports  two  association  groups  with  5  nodes 
support for Grouping 1 and 5 nodes support for Grouping 2.   
This  has  the  effect  that  when  the  unit  is  operating,  all 
devices  associated  with  the  unit  will  receive  the  relevant 
reports. 
 

 When  the  unit  is  powered  for  the  first  time,  the  unit  will 

send a Notification Report to the node of Group 1. 

 When  setting  the  unit  or  changing  the  unit

’s  status,  the 

unit  will  send  a  Binary  Switch  Report  to  the  node  of 
Group 1. 

 When  performing  Reset  the  unit  will  send  Device  Reset 

Locally Notification to the node of Group1. 

 When the button on the unit or the wall switch is pressed, 

the unit will send a Basic Set command to the nodes of 
Group 2.    When the unit is OFF, Basic Set Value = 0x00.   
When the unit is ON, Basic Set Value = 0xFF. 
 
 
 

Z-Wave Plus

TM

 Info 

Role Type 

Node Type 

Installer Icon 

User Icon 

Slave 
Always On 

Z-Wave 
Plus

TM

 node 

On/Off Power 
Switch 

On/Off Power 
Switch 

 

Version 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

7.17.2 

 

Manufacturer 

Manufacturer ID 

Product Type 

Product ID 

0x0060 

0x0034 

0x0001 

 
 
 

AGI (Association Group Information) Table

 

Group  Profile 

Command Class & 
Command (List) N bytes 

Group 
Name(UTF-8) 

General  Binary Switch Report, 

Notification Report, 
Device Reset Locally 
Notification 
Indicator Report 

Lifeline 

Control 

Basic Set 

On/Off control   

 

Basic commands 

Command 

Description 

Basic Get 

Inquire about the status of the device 

Basic Report  Report the status of the device. 
Basic Set 

Set the status of the device.(Value=0XFF 
(ON), 0x00 (OFF)) 

 

Notification 

Event 

Type 

Event 

Event Parameters 
Length 

Power applied for 
first time   

0x08 

0x01 

0x00

 

 

Configuration 

 

The configurable values are as following: 
 
Remember the last status: 

Parameter 
Number 

Size  Range  Default 

Reviews: