background image

     FIGURE 13

OPERATION

By using wall switch to your ES34T, you can easily
select one of two modes of operation: automatic
operation and manual override.

(1) AUTOMATIC OPERATION

Turn on the wall switch.  When the sensor detects
motion, the light automatically turns on.  The built-in
photocell turns the sensor off and on according to the
light level selected by the Lite adjustment.

(2)

 

MANUAL OVERRIDE

To keep the light on regardless of the motion, you can
override the Automatic Operation. Turn the wall switch off
and on twice within 4 seconds. The interval between the
first and second operation must be within 0.5 - 2
seconds.

In Manual Override mode, the light will remain on for
around 4 ~ 6 hours despite no motion; then the light will
turn off and the motion sensor will be back to Auto
Operation mode automatically.

Users can also set the motion sensor back to Auto
Operation by turning off the wall switch for at least 10
seconds and then turn it back on.

TROUBLESHOOTING

Light does not turn on

l

 

Confirm that you have made a correct “wiring
connection”.

l

 

Make sure that the bulbs have not burned out.

Light remains on

l

 

Make sure the wiring connection is correct.

l

 

If you set the system to manual override, remember
that you must turn the wall switch off  for at least 10
seconds to switch the sensor to automatic
operation and turn off the lights.

l

 

Check if the TIME setting is correct.

6

SPECIFICATIONS

Detection Method

Passive infrared

Power Requirement

AC 220 - 240V/ 50Hz

Lighting Load
(Incandescent)

Max. 1,000W
Tungsten
10* Max.40W
Fluorescent

Power Cord Requirement

H05RN-F, 1.0mm

²

Sensor Power

Protection Class

Class II

Waterproof

IP44

Operating

Temperature

-20

°

 C to +40

°

C

Detection Range

Up to 12m (39.4ft) at 20

°

 C,

2m Height

Sensor Adjustments

Detection Angle

Up to 180

°

 at 20

°

C, 2m Height

Swiveling Angle

Vertical 220

°

Warm Up Time

About 1 minute

Time Adjustment

From 5± 3 seconds to
12± 3 minutes

Lux Adjustment

Approx 0 Lux to 1,000Lux.

Mounting Height

1.8 to 2M (5.9 to 6.6 Feet)
Wall Mount
2.5 to 4M (8.2 to13.2 Feet)
Ceiling Mount

Switch Function

Off/Auto/Manual Override

INES34TEVSPEA

.

7

 

Summary of Contents for ES34T

Page 1: ...uit protection or a suitable fuse l The unit can be installed only horizontally see the FIGURE 1a not vertically see the FIGURE 1b as shown in the below drawing HORIZONTAL VERTICAL FIGURE 1a 1b IMPORTANT Some local building codes may require installation of this product by a qualified electrician Check your local codes as they apply to your situation If the house wiring is of aluminum consult with...

Page 2: ... Type I FIGURE 4 Type II FIGURE 5 2 Note The detection angle of ES34T can come up to180 However to reduce or localize its detection coverage use the small plastic slip s provided to cover up part s of the LENS thus reducing its detection angle FIGURE 6 FIGURE 6 WIRING INSTRUCTION 1 Switch off the power source or wall switch 2 Unscrew two front screws to detach the base cover from the unit FIGURE 7...

Page 3: ...ight will turn on for about 1 minute to warm up Then it turns off l Walk through the detection area The light turns on when you move and turns off when you stop Wait for the light to turn off before moving again to test the sensor l Adjust the motion sensor to cover the desired detection area For a smaller coverage area point the sensor down for a larger coverage area point the sensor up 2 TIME AD...

Page 4: ...it back on TROUBLESHOOTING Light does not turn on l Confirm that you have made a correct wiring connection l Make sure that the bulbs have not burned out Light remains on l Make sure the wiring connection is correct l If you set the system to manual override remember that you must turn the wall switch off for at least 10 seconds to switch the sensor to automatic operation and turn off the lights l...

Reviews: