4.2. Requirement prior to initial commissioning
A few preparations are necessary before your service engineer can set up your machine. The following
preparations must be carried out by a professionally qualified person.
Description
OK
Issue
Flat and clean surface
Clean environment
Space above min. 250 mm (11.8 in)
Stable table capable of bearing up to:
• 70 kg (Cameo, Légacy, E'2c, Shotmaster c)
• 110 kg (E'2, E'4, Shotmaster s, Shotmaster ms)
• 140 kg (E'4 x-wide)
• 170 kg (E'6, Shotmaster s-pro, Shotmaster ms-pro)
Table height 800 mm (31.5 in)
Countertop cutout, download here:
Separate electrical lines for each machine
Electrical mains protected by RCD or RCCB
Water mains shutoff valve with a non-return valve (type EA or accord-
ing to local regulation)
Descaling cartridge or carbon filter as minimum
Water pressure 2.5 - 4 bars (32.3 - 58 psi) (250 - 400 KPa)
Pressure reducer (only if pressure is above 4 bars)
Flow rate above 200 L/h (Enigma, Shotmaster, E’line)
Flow rate above 150 L/h (E'2c, Shotmaster c)
Flow rate above 140 L/h (Cameo, Légacy)
Water inlet 3/8" (AU and JA G 1/2)
The drain hose must be connected to a siphon (input min. Ø 56 mm
(Ø 2.2 in)
Siphon input min. Ø 56 mm (Ø 2.2 in) according to EN 61770
Machine installed with adequate back flow protection to comply with
applicable federal, state or local plumbing codes
Total hardness: 5 - 8° dGH (89-142 ppm)
Carbonate hardness: Max. 6° dKH (107 ppm)
pH value: ideal 7.0 - 7.2
Chlorine (Cl) max. 10 mg/l
Commissioning
Page 45 of 161
Published on 29.06.2022
Legacy User Manual © Eversys S.A.
Summary of Contents for LEGACY L'2c/Classic
Page 1: ...User Manual Published on 29 06 2022 ...
Page 2: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 42: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 46: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 66: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 74: ...Settings Menu Legacy User Manual Eversys S A Published on 29 06 2022 Page 74 of 161 ...
Page 77: ...Settings Menu Page 77 of 161 Published on 29 06 2022 Legacy User Manual Eversys S A ...
Page 82: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 128: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 146: ...This page is intentionally left blank Published on 29 06 2022 ...
Page 147: ...11 Appendix Appendix Page 147 of 161 Published on 29 06 2022 Legacy User Manual Eversys S A ...
Page 162: ......
Page 163: ......