LTC Power Out OK
The LTC 1 Output Power is operating normally
LTC Overloaded
The LTC 1 Output Power is overloaded. This usually means that there
is a short in the LTC 1 cabling or there are too many clocks drawing
power from the LTC1 output.
3.3.7. Power Supply Status Messages
P.S. x FAIL
Power Supply 1 or 2 is not working
P.S. x OK
Power Supply 1 or 2 is working
3.3.8. GPI Input Supply Status Messages
GPIx input xxxx
Shows the state of GPI 1 or GPI2 input (high or low)
3.3.9. Cooling Fan Status Messages
Fans Ok
Both of the cooling fans are working
Fan
Failure
One of the cooling fans is not working
Both Fans Failed
Both of the cooling fans are not working
3.3.10. Synchro Status Messages
Syncro not RX
The syncro mode is not RX or syncro time.
Syncro link OK
The syncro mode is RX or syncro time, and receiving data ok.
Syncro link OK
The syncro mode is RX or syncro time, and not receiving data.
3.3.11. Flashing Leds
Leds are flashing
When a system jam is needed, any leds that are on, will be flashing.
See section 3.5.5).
3.4.
AN OVERVIEW OF THE SETUP MENU SYSTEM
The key to the operational flexibility of the 5600MSC lies in the
Setup
menu system. The
Setup
menu
system uses the 16 digit alphanumeric display and provides a quick, intuitive method of configuring
5600MSC, guiding you to the correct setup for your application.
The 5600MSC menu system consists of three main menus with several choices for each menu item.
The
INPUT, OUTPUT
and
GENERAL
keys allow you to quickly go to each of the three main menus,
while the
SELECT, ESC,
Ï
,
Ð
and
SHAFT ENCODER
knob are used to navigate the menu.
To enter the
INPUT SETUP
menu, press the
INPUT
key. Similarly you can enter the
OUTPUT SETUP
or
GENERAL SETUP
menus by pressing the
OUTPUT
and
GENERAL
keys respectively. Once you
are in one of the three main menus, the top level menu items are shown in UPPER CASE. Use the
arrow keys (
Ï
,
Ð
) or turn the
SHAFT ENCODER
knob to display the desired item within the top level
menu and press the
SELECT
key. There may be a sub-menu layer shown in Title Case (The First
Letter Of Each Word Is Capitalized). If there is another menu level, use the arrow keys (
Ï
,
Ð
) or turn
the
SHAFT ENCODER
knob to display the desired item within the sub-menu and press the
SELECT
key to get to the bottom of the menu tree where the displayed parameters to be adjusted will be shown
USO