TECHNICAL DESCRIPTIONOPERATION
Revision 1.6
Page
3-13
When set to
25 Hz LTC tm ref
the 5600MSC system time is referenced to
time information being read at the LTC input port. The incoming time must
be 25 Frames per second.
When set to
25 Hz LTC tm nd
the 5600MSC system time is referenced to
time information being read at the LTC input port. The incoming time must
be 25 Frames per second. The 5600MSC will not read any date information
in the LTC. Use this if the incoming LTC has no date information
embedded.
When set to
29.97df LTC ref
the 5600MSC system time is referenced to
time information being read at the LTC input port. The incoming time must
be 29.97 Frames per second drop frame.
When set to
29.97df LTC nd
the 5600MSC system time is referenced to
time information being read at the LTC input port. The incoming time must
be 29.97 Frames per second drop frame. The 5600MSC will not read any
date information in the LTC. Use this if the incoming LTC has no date
information embedded.
When set to
NTSC VITC tm ref
the 5600MSC system time is referenced to
time information being read from VITC on the video genlock input when a
PAL colour black genlock is supplied. The incoming VITC time must be
29.97 Frames per second drop frame.
When set to
NTSC VITC tm nd
the 5600MSC system time is referenced to
time information being read from VITC on the video genlock input when a
PAL colour black genlock is supplied. The incoming VITC time must be
29.97 Frames per second drop frame. The 5600MSC will not read any date
information in the VITC. Use this if the incoming VITC has no date
information embedded.
When set to
PAL VITC tm ref
the 5600MSC system time is referenced to
time information being read from VITC on the video genlock input when a
PAL colour black genlock is supplied. The incoming VITC time must be 25
Frames per second.
When set to
PAL VITC tm nd
the 5600MSC system time is referenced to
time information being read from VITC on the video genlock input when a
PAL colour black genlock is supplied. The incoming VITC time must be 25
Frames per second. The 5600MSC will not read any date information in the
VITC. Use this if the incoming VITC has no date information embedded.
"
When using VITC as a time reference, the FREQUENCY REF menu item must be set
to Video freq ref.
USO