Model 5601MSC
Model 5601MSC Master SPG/Master Clock System
Page - 104
Revision 2.2
MASTER CLOCK
Sync 1
into the vertical blanking interval of the sync output.
This menu item is only applicable when the Sync
Mode
is set to the
PAL-B
or
NTSC-M
formats and will disabled for other formats (shown in dark text).
Vitc Ctl
Off
On
4.4.2.2.2.
Selecting the VITC Insertion Lines
OUTPUT
These menu items select the lines onto which the VITC will be inserted
when the
Vitc Ctl
menu item is set to
On
. If only one line of VITC is desired,
set both menu items to the same line.
The default line values for NTSC-M are lines 14 and 16.
The default line values for PAL-B are lines 17 and 17 (same line).
This menu item is only applicable when the Sync
Mode
is set to the
PAL-B
or
NTSC-M
formats and will be disabled for other formats (shown in dark
text).
Sync 1
Vitc Line 1
line 1 = 14
Vitc Line 2
line 2 = 16
4.4.2.2.3.
Enabling Dropframe Counting for NTSC VITC
OUTPUT
This menu item allows the user to control whether the dropframe counting
mode will be used for the VITC inserted onto the sync output.
This menu item is only applicable to the NTSC-M format and will be
disabled for all other formats (shown in dark text).
Sync 1
Dropframe Ctl
Off
On
4.4.2.2.4.
Enabling Colorframe Alignment of VITC
OUTPUT
This menu enables or disables color frame alignment of VITC timecode to
the black burst sync it is being embedded on. This menu item is only
applicable when the sync mode is NTSC-M or PAL-B.
When turned on, the Color Frame bit in VITC will be set to indicate that color
frame alignment is being performed. The VITC timecode count will be
adjusted to maintain a correlation to the color field it is inserted on according
to SMPTE ST 12-1 (see section 2.3.4.2 for more detail).
Sync 1
Color Frame
Color Frame Off