Page - 71
Figure 4-2 : Status Screen Highlighting to Indicate Warnings and Faults
The status screens are described in detail below. Each status screen can display multiple messages
depending on the configuration of the 5601MSC.
Pressing the STATUS button and scrolling through the status screen names is
a quick way to see if there are any problems with the 5601MSC. Screens that
are in fault or warning conditions will be highlighted RED or YELLOW.
System / In time
hh:mm:ss:ff
The
System/In time
status screen shows the system clock time and date on the
first two lines.
The third line, prefixed with “
L i
", shows the current LTC timecode being read
from the LTC/IRIG input (if present). If the LTC input is lost, the time shown here
will be replaced with “
--:--:--:--
”. If drop frame is detected, the last colon ‘
:
’
will be replaced with a period ‘
.
’.
The fourth line, prefixed with “
V i
", shows the current timecode being read from
VITC on the reference input. If the VITC input is lost, the time shown here will be
replaced with “
--:--:--:--
“. If drop frame is detected, the last colon ‘
:
’ will be
replaced with a period ‘
.
’.
The fifth line, prefixed with “
I
”, shows the current IRIG timecode being read from
the LTC/IRIG input (if present). If the IRIG input is lost, the time shown here will be
replaced with “
--:--:--:--
“.