570J2K-HW-X19
Multi channel J2K Encoder-Decoder
Revision 1.0
Page - 25
5.8.
SYSTEM NOTIFY
Figure
5-14 : WebEASY
®
- System Notify Tab
5.8.1. System Monitoring Control
Temperature Warning Threshold:
This control allows the user to set the temperature threshold. If the
temperature exceeds the configured temperature threshold, the temperate status will change to active.
Received Bandwidth Threshold:
Reserved for future use.
5.8.2. System Notify
Temperature Traps:
This control allows the user to turn Enable/Disable the Temperature Trap.
Temperature Faults:
This temperature status is highlighted with this parameter. If a fault is active: the
temperature exceeds the temperature threshold, it is reflected with a red status. If a fault is inactive, it
is reflected as a green status.
Port Link Status SFP1:
This status highlights Data 1 port status. If the port is up, the status will be
inactive / green. If the port is down, the status will be active / red.
Port Link SFP1 Trap:
This control allows the user to enable trap receiving when the port 1 is down
and an associated correction trap when the port is up.
Port Link Status SFP2:
This status highlights Data 2 port status. If the port is up, the status will be
inactive / green. If the port is down, the status will be active / red.
Port Link SFP2 Trap:
This control allows the user to enable trap receiving when the port 2 is down
and an associated correction trap when the port is up.
Port Link Status SFP3:
This status highlights Data 3 port status. If the port is up, the status will be
inactive / green. If the port is down, the status will be active / red.