background image

7700 MultiFrame Manual 

7780ASIB2-DS3/E3 2 Channel ASI + Ethernet DS3/E3 Transceiver 

 Revision 

2.0 

Page - 15 

4.2.2.4. 

Displaying the Output ASI Bandwidth Used 

This menu selection displays the combined bandwidths used for the 2 video channels.  To display the 

Total Output Bandwidth Used

 from the 

STAT

 menu, use the toggle switch/pushbutton to select the 

OASI

 

menu and then choose 

OPBW

, followed by 

USED

 

STAT 

OASI 

OPBW 

USED 

 

The following indications are possible: 
 

USED

               

Combined Output Bandwidth 

 

 

4.2.2.5. 

Displaying the TDMD Data Errors 

This menu selection displays the errors in the clear channel TDM data.  This allows user to monitor if 
transmission errors are occurring at the DS3/E3 network or at the TDM stream.  To display the 

TDMD 

Data Error

 from the 

STAT

 menu, use the toggle switch/pushbutton to select the 

TDMD

 menu. 

  

STAT 

TDMD 

LOSS  
ERR 
OK 
 

 

The following indications are possible: 
 

LOSS

                TDM Data Lost 

ERR        

TDM Error Detected 

OK

                   TDM Data is present and no errors are detected 

 

4.2.2.6. 

Displaying the Ethernet Status 

This menu selection displays the 

Ethernet Status

.  To display the 

Ethernet Status

 from the 

STAT

 menu, 

use the toggle switch/pushbutton to select the 

ETH

 menu and then choose 

LINK

.

 

 

STAT 

 

ETH 

 

LINK 

 

UP 
DOWN 

 

The following indications are possible: 
 

UP

                Ethernet input present 

DOWN

            Ethernet input not present 

 

4.2.2.7. 

Displaying the Ethernet Speed 

This menu selection displays the 

Ethernet Transmission Speed

.  To display the 

Ethernet Transmission 

Speed

 from the 

STAT

 menu, use the toggle switch/pushbutton to select the 

ETH

 menu and then choose 

SPD. 

 

STAT 

 

ETH 

 

SPD 

 

10 
100 
DOWN 

 

The following indications are possible: 
 

10

                         10Mb/s Ethernet Link established 

100

                       

100Mb/s Ethernet Link established 

DOWN

                     

No Ethernet Link established 

 

Summary of Contents for 7780ASIB2-DS3/E3

Page 1: ...he Card Edge Display 13 4 2 2 STAT Menu 13 4 2 2 1 Displaying Input ASI Status Information 14 4 2 2 2 Displaying the Total Input ASI Bandwidth Used 14 4 2 2 3 Displaying Output ASI Status Information 14 4 2 2 4 Displaying the Output ASI Bandwidth Used 15 4 2 2 5 Displaying the TDMD Data Errors 15 4 2 2 6 Displaying the Ethernet Status 15 4 2 2 7 Displaying the Ethernet Speed 15 4 2 2 8 Displaying ...

Page 2: ...RD MINI AGENT IS USED 28 7 3 VISTALINK MONITORED PARAMETERS 30 7 4 VISTALINK CONTROLLED PARAMETERS 31 7 5 VISTALINK TRAPS 31 Figures Figure 1 1 7780ASIB2 DS3 E3 Block Diagram 2 Figure 2 1 7780ASIB2 DS3 E3 Rear Panel 3 Figure 4 1 Location of Status Indicators and Controls 7 Figure 4 2 Card Edge Menu 10 Figure 5 1 General Tab 18 Figure 5 2 Errored Second Control Tab 19 Figure 5 3 Errored Second Stat...

Page 3: ...ot warranties of future performance either expressed or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed ...

Page 4: ...7700 MultiFrame Manual 7780ASIB2 DS3 E3 2 Channel ASI Ethernet DS3 E3 Transceiver Revision 2 0 This page left intentionally blank ...

Page 5: ... 1RU frame Features Transports signal over DS3 E3 data rates 44 736Mb s Single card TDM multiplexer and demultiplexer for two bi directional asynchronous DVB ASI signals Built in Ethernet transceiver with one 10 100 Base T port with FBM Flexible Bandwidth Management Interfaces directly to DS3 E3 infrastructure Signal transport uninterrupted by loss of any DVB ASI input feed Wide input frequency ra...

Page 6: ...DM MUX Input Stage Output Stage Input Stage DS3 E3 SDH TDM DEMUX Output Stage Output Stage Input Stage CONTROL INDICATION LOCAL CONTROL VistaLINK Interface LOCAL INDICATION DS3 E3 OUTPUT DS3 E3 INPUT 2 ASI INPUT 2 ASI OUTPUTS 10 100 ETHERNET RJ45 1 2 1 2 FBM Technology Figure 1 1 7780ASIB2 DS3 E3 Block Diagram ...

Page 7: ...to the frame see section 3 of the 7700FR chapter Figure 2 1 7780ASIB2 DS3 E3 Rear Panel ASI IN 1 2 Two independent BNC input connectors compatible with DVB ASI for a combined usable system bandwidth of 40Mb s These inputs provide adaptive compensation for up to 250m of industry standard Belden 1694A cable ASI OUT 1 2 Two independent BNC output connectors compatible with DVB ASI for a combined usab...

Page 8: ... and receive of 10 100 Base T Ethernet signal with a max bandwidth of 25Mbps Total system bandwidth may not exceed 40Mbps CONTROL PORT Allow the onboard SNMP miniagent to communicate over SNMP to the management network VistaLINK Please Note Total System Bandwidth includes bandwidth allocated for 2 ASI inputs plus 1 Ethernet transport signal Please Note GPIO port is currently unavailable at the tim...

Page 9: ...ppm 3 2 SERIAL VIDEO OUTPUTS Standards DVB ASI Number of Outputs 2 independent DVB ASI signals with combined total system bandwidth of 40Mb s Connectors BNC per IEC 61169 8 Annex A Signal Level 800mV nominal DC Offset 0V 0 5V Rise and Fall Time 900ps nominal Overshoot 10 of amplitude Return Loss 12dB Wide Band Jitter 0 2UI 3 3 LINK OUTPUT Standards DS3 E3 Number of Outputs 1 Connector BNC per IEC ...

Page 10: ... Listed to CSA C22 2 No 60065 03 UL 60065 03 IEC 60065 2001 12 7th Edition Complies with CE Low voltage directive 93 68 EEC Laser Safety Complies with 24 CFR 1040 10 and 1040 11 except for deviations pursuant to LN No 50 dated July 26 2001 Complies with IEC 60825 1 Am 2 EMI RFI Complies with FCC regulations for class A devices Complies with EU EMC directive 89 336 EEC ...

Page 11: ...ATOR LEDS LOCAL FAULT On the 7780ASIB2 DS3 E3 board this Red LED will be ON if no valid link input signal is present or if a local input power fault exists i e a blown fuse The LOCAL FAULT indications can also be reported to the frame through the FRAME STATUS jumper MODULE OK This Green LED indicates good module health It will be ON when a valid link input signal is present and board powers are go...

Page 12: ...de or setting control parameters for the card control mode Press the toggle switch to select control mode CTRL or monitor mode STAT Figure 4 2 shows the menu structure for the 7780ASIB2 DS3 E3 card LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 OK LINK ERR BACK BACK BACK PSWL BACK MAN ETH MODE AUTO BACK EN OUTP DIS IN1 MAXB 0 40 BACK EN OUTP DIS IN2 MAXB 0 40 BACK EN OUT1 OUTP DIS BACK EN PSWD OUT2 OUTP ...

Page 13: ...on 2 0 Page 9 BACK BACK ALL CLR BACK 15m CLR BACK CIC 24h CLR HORZ DISP VERT BACK BACK RATE NULL DATA PID ASI1 CCER BACK RATE NULL DATA PID ASI2 CCER BACK IASI IPBW USED BACK BACK RATE NULL DATA PID ASI1 CCER BACK RATE NULL DATA PID ASI2 CCER BACK OASI OPBW USED BACK LOSS ERR STAT TDMD OK ...

Page 14: ...ge 10 Revision 2 0 BACK BACK UP LINK DOWN BACK 10 100 SPD DOWN BACK ETH BW 0 25 BACK BACK BACK TIME LOSS OOF AIS RAI IDLE 15m SEF BACK TIME LOSS OOF AIS RAI IDLE CIC 24h SEF BACK BACK LOSS OOF AIS RAI IDLE 15m SEF BACK LOSS OOF AIS RAI IDLE DS3 LIC 24h SEF VER Figure 4 2 Card Edge Menu ...

Page 15: ... menu item and then choose the PSWL menu item A new passcode may then be selected and stored CTRL PSWD PSWL 0 to 9999 The following selections are available PSWL Store a new passcode 0 9999 This menu is not available without first entering the correct passcode For Ethernet transport the user may select between two modes of operation Manual and Auto In Manual mode the user defines the bandwidth all...

Page 16: ...oose the OUT1 or OUT2 menu item CTRL PSWD OUT1 OUT2 OUTP EN DIS The following selections are available EN Enable Input Channel DIS Disable Input Channel When Disabled data on the selected signal is not placed on the output BNC data stream 4 2 1 2 Input ASI Output ASI Error Reset The ASI Continuity Error Counter clear can be controlled using menu selections To clear the ASI Continuity Error Counter...

Page 17: ...timer clear can be controlled using menu selections To configure the counter timer clear from the CTRL menu use the toggle switch pushbutton to select the CIC menu item CTRL CIC ALL 15m 24h CLR The following selections are available ALL CLR to clear both counters 15m CLR to clear the 15 minute counter 24h CLR to clear the 24 hour counter 4 2 1 5 Setting the Orientation of the Text on the Card Edge...

Page 18: ...andwidth Used This menu selection displays the sum of the 2 input channel bandwidths To display the Total Input Bandwidth used from the STAT menu use the toggle switch pushbutton to select the IASI menu and then choose IPBW followed by USED STAT IASI IPBW USED The following indications are possible USED Combined Input Bandwidth 4 2 2 3 Displaying Output ASI Status Information This menu selection d...

Page 19: ...use the toggle switch pushbutton to select the TDMD menu STAT TDMD LOSS ERR OK The following indications are possible LOSS TDM Data Lost ERR TDM Error Detected OK TDM Data is present and no errors are detected 4 2 2 6 Displaying the Ethernet Status This menu selection displays the Ethernet Status To display the Ethernet Status from the STAT menu use the toggle switch pushbutton to select the ETH m...

Page 20: ...tegrity To display performance counters from the STAT menu use the toggle switch pushbutton to select the DS3 menu item and then choose the CIC menu item The module records the Current performance over 15 minute and 24 hour intervals which restart once they have expired The corresponding status is displayed by selecting either the 15m or 24h menu item To display the current timer value select TIME...

Page 21: ...ds Last interval counts for 15 minute and 24 hour intervals The corresponding status is displayed by selecting either the 15m or 24h menu item The following selections are available to display performance counts STAT DS3 LIC 15m 24h LOSS OOF AIS RAI IDLE SEF The following indications are possible LOSS Signal Loss OOF Out Of Frame AIS Alarm Indication Signal RAI Remote Alarm Indication IDLE DS3 Idl...

Page 22: ...rd Enables the user to set store new passwords Clear Counters Enables the user to clear all counters and reset the timer Remote Reset Enables the user to remotely reset the 7780ASIB2 DS3 E3 card module 5 1 2 Ethernet Control Ethernet Mode Enables the user to set Manual or Auto Ethernet mode 5 1 3 Monitor The Monitor section indicates the card model number TDMD status and current firmware version 5...

Page 23: ... ASI Ethernet DS3 E3 Transceiver Revision 2 0 Page 19 5 2 ERRORED SECOND CONTROL The Errored Second Control tab as illustrated in Figure 5 2 enables the user to clear the 15 minute counter and the 24 hour counter Figure 5 2 Errored Second Control Tab ...

Page 24: ... the current 15 minute and current 24 hour performance counters as well as the last 15 minute and last 24 hour performance counters The counters include Out of Frame Signal Loss Alarm Indication Signal Severely Errored Frame Remote Alarm Indication and DS3 Idle Signal The Interval Elapsed Time indicates the current timer on the 15 minute and 24 hour counters Figure 5 3 Errored Second Status Tab ...

Page 25: ...dwidths Input Used Data Bitrate It also indicates the combined bandwidths used for the 2 video channels Output Used Data Bitrate Figure 5 4 ASI Bandwidth Monitor Tab 5 5 ASI INPUT 1 This tab illustrated in Figure 5 5 enables the user to set ASI Input controls and monitor ASI Input status information For the sake of brevity only ASI Input 1 will be described Figure 5 5 ASI Input 1 Tab ...

Page 26: ... PIDs and Continuity Error Count 5 6 ASI OUTPUT 1 This tab illustrated in Figure 5 6 enables the user to set ASI Output controls and monitor ASI Output status information For the sake of brevity only ASI Output 1 will be described Figure 5 6 ASI Output 1 Tab 5 6 1 Control Reset Measurement Enables the user to reset Output Continuity Error Counter to 0 ASI Enable Allows the user to enable or disabl...

Page 27: ... status To enable a particular trap simply click the box located beside each trap so that a check mark appears When a check mark is present the trap is enabled When a check mark is not present the trap is disabled The ASI Trap Status section defines whether a trap is present or missing If the box is green then the corresponding trap is present If the box is red then the corresponding trap is missi...

Page 28: ...tatus To enable a particular trap simply click the box located beside each trap so that a check mark appears When a check mark is present the trap is enabled When a check mark is not present the trap is disabled The Trap Status section defines whether a trap is present or missing If the box is green then the corresponding trap is present If the box is red then the corresponding trap is missing Fig...

Page 29: ...ers 6 1 SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME STATUS The FRAME STATUS jumper determines whether local faults as shown by the Local Fault indicator will be connected to the 7700FR frame s global status bus Each of the cards of the module pair has a frame status jumper Be sure to change both jumpers to the same state FRAME STATUS To monitor faults on this module with t...

Page 30: ...l pouch in the front of this manual onto the SERIAL header at the card edge Re install the module into the frame Run the upgrade as described in the Upgrading Firmware section in the front of this manual binder Once the upgrade is complete remove the module from the frame move the UPGRADE jumper into the RUN position remove the upgrade cable and re install the module The module is now ready for no...

Page 31: ...gement System NMS is a computer running special software that communicates with the devices in the network Evertz VL Fiber demo Manager graphical user interface GUI third party or custom manager software may be used to monitor and control Evertz VistaLINK enabled fiber optic products 2 Managed devices such as 7780ASIB2 DS3 E3 cards each with a unique address OID communicate with the NMS through an...

Page 32: ...NTER to display the card s main menu Make a selection by typing in the selection number at the prompt and pressing ENTER 3 Select 01 to enter the Network Configuration to make changes to the network settings 4 When done Type S and ENTER to save the changes 5 At the main menu select 02 to enter the SNMP Configuration to add SNMP trap destinations 6 Select 01 to add new or delete existing SNMP trap ...

Page 33: ...B2 DS3 E3 2 Channel ASI Ethernet DS3 E3 Transceiver Revision 2 0 Page 29 7 Type X and ENTER to exit 8 Type S and ENTER to save the changes Please Note VLPro traps will be added in the next release when using only the SNMP mini agent ...

Page 34: ...terval Performance Counters Indicates the last 15 minute and last 24 hour performance counters Signal Loss Out of Frame Alarm Indication Signal Remote Alarm Indication DS3 Idle Signal and Severely Errored Frame Interval Elapsed Time Indicates the current timer on 15 minute and 24 hour counter Input Used Data Bitrate Indicates the sum of the two input channel bandwidths Output Used Data Bitrate Ind...

Page 35: ...ut Bandwidth Mb s ASI Output Mode Allows to user to set ASI output to Continuous or Discontinuous mode Table 7 2 VistaLINK Controlled Parameters 7 5 VISTALINK TRAPS The following traps can be VistaLINK enabled and monitored Trap Description Input and Output ASI Loss Triggers when there is a loss of a valid video signal on channels 1 and 2 Input Bandwidth Triggers when Input 1 and 2 bandwidth is ex...

Page 36: ...7700 MultiFrame Manual 7780ASIB2 DS3 E3 2 Channel ASI Ethernet DS3 E3 Transceiver Page 32 Revision 2 0 This page left intentionally blank ...

Reviews: