background image

7780MD Series  

DVB-S/S2/S2X L-Band and IF Satellite Modulators

 

 

Page - 18

 

Revision 1.0

 

 

Auto RF Power Off Conditions 

Stream Input Loss: 

This parameter sets auto mute on ASI error. 

 

4.4. 

IP INPUT 

 

Figure 

 

4-4 : IP Input Tab 

 

IP Input Configuration 

VLANID: 

This parameter sets the VLAN identifier. 0 means VLAN is disabled.

 

Mode: 

This parameter controls the reception mode.

 

IGMP Version: 

This parameter controls the IGMP version.

 

Summary of Contents for 7780MD Series

Page 1: ...nformation that is the property of Evertz Microsystems and is intended solely for the use of purchasers of 7780MD Series Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 7780MD Series Due to on going research and development features and specifications in this manual are subject to change without notice All rights reserved No part of th...

Page 2: ...This page left intentionally blank ...

Page 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Page 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Page 5: ...HARDWARE INSTALLATION 5 2 3 CONFIGURATION OF MANAGEMENT IP CONNECTION 6 2 4 HTTP BROWSER CONTROL 7 2 5 SETTING UP USER LOGIN CREDENTIALS AND CHANGES PRIVILEGES 8 3 SPECIFICATIONS 9 ASI INPUTS 9 ASI OUTPUT 9 IP INPUT 9 CONTROL 9 7780MD IF OUTPUT 9 7780MD LB OUTPUT 10 MONITORING PORT 10 MODULATION 10 DVB S 10 DVB S2 10 DVB S2X BROADCAST DSNG PROFILES OPTIONAL 10 ELECTRICAL 11 PHYSICAL NUMBER OF SLOT...

Page 6: ...e 2 3 Main Menu Prompt 6 Figure 2 4 Network Setup Screen 7 Figure 2 5 FC Menu WEBEASY Interface 8 Figure 4 1 General Tab 13 Figure 4 2 Configuration Tab 15 Figure 4 3 RF Output Tab 17 Figure 4 4 IP Input Tab 18 Figure 4 5 Carrier ID Tab 20 Figure 4 6 Monitor Tab 21 Figure 4 7 Presets Tab 23 Figure 4 8 Alarms Tab 25 Figure 5 1 Upgrade Button 27 Figure 5 2 Selecting the 7780MD 27 Figure 5 3 Verifyin...

Page 7: ...ied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically u...

Page 8: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page iv Revision 1 0 This page left intentionally blank ...

Page 9: ... compliant with modulation schemes available up to 32ASPK Wideband output frequency range adjustable from 950MHz to 2150MHz for LB option and 50MHz to 180MHz for IF option Symbol rates range from 1 to 68 MSps Monitoring port provided for local monitoring of signal integrity Dual selectable ASI and IP inputs for flexibility in system configuration and selection of various accompanying encoder modul...

Page 10: ...INFORMATION 7780MD IF DVB S S2 modulator IF output 7780MD LB DVB S S2 modulator L Band output 1 3 ORDERING OPTIONS DBISS License for BISS 1 E Encryption DVB S2X License to enable DVB S2X Broadcast and DSNG profiles modulation standards S50 50Ω SMA connectors Figure 1 1 7780MD Series Block Diagram ...

Page 11: ...3 2 INSTALLATION 2 1 REAR PLATE DESCRIPTION Figure 2 1 provides an illustration of the 7780MD series rear plate Figure 2 1 7780MD Series Rear Plate 2 1 1 Connectors RF MON Output BNC 50 Ohm connector for monitoring L band output RF OUT Output BNC 50 Ohm connector for L band output ...

Page 12: ...te Green White Orange Used Used 2 Transmit Green White or White Orange White or Orange Used Used 3 Receive White Orange White Green Used Used 4 Bi dir Blue White or Blue Blue White or Blue Used 5 Bi dir White Blue White Blue Used 6 Receive Orange White or Orange Green White or Green Used Used 7 Bi dir White Brown White Brown Used 8 Bi dir Brown White or Brown Brown White or Brown Used Table 2 1 St...

Page 13: ...ia a 780x Frame controller and cannot be controlled directly through its own control port 2 2 HARDWARE INSTALLATION Before handling the card it is important to minimize the potential effects of static electricity It is therefore recommended that an ESD strap be worn Locate on the 7800 chassis two adjacent vacant slots Unpack the 7780MD and separate the rear panel from the main card Locate on the r...

Page 14: ...he steps below 1 Remove the panel by unscrewing both knobs on the side 2 Connect the serial upgrade cable ribbon cable provided by Evertz to the 2x3 header at the front edge of the 7801FC 7800FC 3 Open a terminal program such as HyperTerminal Setup the terminal program as shown in Figure 2 2 Figure 2 2 COM Port Settings 4 Power on the unit and allow unit to boot up 5 After boot up press ENTER and ...

Page 15: ...MD using an HTTP browser by following these steps 1 Connect a network cable RJ 45 between the management connector labelled ETHERNET on the chassis and the LAN connector of the local PC or switch 2 Open Firefox or Chrome browser latest version recommended and type in the control port IP address from Section 2 3 Note The PC used for management and administrative purposes must be in the same subnet ...

Page 16: ...ick on any of the tabs on the left side e g Hardware tab Login using login admin password admin Click the Users button on the lower right side Under the Users tab click the Modify button for customer and change its role to RW Logout of the FC and login as customer customer Re login to the FC The user needs to follow the same steps for the DEMODULATOR User needs to login to the card directly with h...

Page 17: ...ss 15dB IP INPUT Number 1 Connector RJ45 10 100 1000 GigE for MPEG over IP Max Bit Rate 200Mbps CONTROL SNMP over Ethernet via FC Web browser via FC 7780MD IF OUTPUT IF Out 1 Connector BNC per IEC 61169 8 Annex A Impedance 75Ω Return Loss 12dB P1dB 18dBm Output Level 35dBm to 5dBm Frequency Range 50 to 180MHz Frequency Stability of Internal 10MHz clock with respect to Temperature 2 5ppm over 0 to ...

Page 18: ...8 MSps Roll off Factor 0 05 0 10 0 20 0 25 0 35 Multiplex Adaptation and Energy Dispersal ETSI EN 300 421 DVB S Compliant EN 302 307 DVB S2 DVB S Operation Mode QPSK 1 2 2 3 3 4 5 6 7 8 8PSK 2 3 5 6 8 9 16QAM 3 4 7 8 Interleaving Depth 12 FEC Reed Solomon 204 188 T 8 Viterbi DVB S2 Operation Mode QPSK 1 4 1 3 2 5 1 2 3 5 2 3 3 4 4 5 5 6 8 9 9 10 8PSK 3 5 2 3 3 4 5 6 8 9 9 10 16APSK 2 3 3 4 4 5 5 6...

Page 19: ... 8 9 9 10 8PSK 3 5 2 3 3 4 5 6 8 9 9 10 16APSK 2 3 3 4 4 5 5 6 8 9 9 10 32APSK 3 4 4 5 5 6 8 9 9 10 FEC BCH LDPC PL Scrambling Codes 0 264143 DVB S2 Short 16 200 Normal 64 800 DSNG Profile 64APSK All new linear MODCOD for QPSK 8PSK 16A 32 64APSK ELECTRICAL Voltage 12V DC Power 27 W PHYSICAL NUMBER OF SLOTS 3700FR 2 7800FR 2 ...

Page 20: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page 12 Revision 1 0 This page left intentionally blank ...

Page 21: ...ser to configure Control and Data Port Settings Figure 4 1 General Tab IP Address This parameter allows the user to define the IP address for the Ethernet port Subnet Mask This parameter allows the user to define the netmask address for the Ethernet port Gateway This parameter allows the user to define the gateway address for the Ethernet port MAC Address This parameter allows the user to define t...

Page 22: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page 14 Revision 1 0 100 Base T Half Duplex 1000 Base T Full Duplex 1000 Base T Half Duplex ...

Page 23: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Revision 1 0 Page 15 4 2 CONFIGURATION Figure 4 2 Configuration Tab ...

Page 24: ...ing Mode This parameter controls the operating mode when the standard is DVBS2 Insert Pilot This parameter controls the pilot insertion when the standard is DVBS2 and the input stream is set to single stream Frame This parameter controls the frame type when the standard is DVBS2 and the input stream is set to single stream Roll Off This parameter controls the roll off factor when the standard is D...

Page 25: ...s parameter controls tilt correction Units are dB MHz Output Level This parameter controls the RF output power level Output Frequency This parameter sets the RF frequency Output Parameters Carrier Modulated This parameter controls carrier modulated It sets sinus mode or carrier is modulated RF Output This control is used to mute the RF board in case of error RF Power On Type This parameter sets th...

Page 26: ...onditions Stream Input Loss This parameter sets auto mute on ASI error 4 4 IP INPUT Figure 4 4 IP Input Tab IP Input Configuration VLANID This parameter sets the VLAN identifier 0 means VLAN is disabled Mode This parameter controls the reception mode IGMP Version This parameter controls the IGMP version ...

Page 27: ...GMPV3 Monitor IP Preset This is the IP address set and stored as preset in firmware IP Status This is the IP address read from the module IP Input Monitoring Protocol This parameter displays the protocol detected FEC Mode This parameter displays the FEC mode FER This parameter displays the estimated Packet Error Rate PER before applying FEC Corrected Frames This parameter is a corrected packet cou...

Page 28: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page 20 Revision 1 0 4 5 CARRIER ID Figure 4 5 Carrier ID Tab ...

Page 29: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Revision 1 0 Page 21 4 6 MONITOR Figure 4 6 Monitor Tab ...

Page 30: ... the modulation and FEC Operating Mode This parameter monitors the operating mode Pilot This parameter monitors the pilots insertion FEC Frame Length This parameter monitors the frame type Roll Off Factor This parameter monitors the roll off factor Test Mode This parameter monitors the test mode Rate Adaptation This parameter monitors the rate adaptation Symbol Rate This parameter monitors the sym...

Page 31: ...the name in the Name field and click Apply c Click on the Store button to create the saved preset d A dialog box will appear saying Are you sure you want to store presets for this user Click OK to store e Follow the above steps to create up to 5 presets Recalling a Preset 1 The user can select which preset to recall by clicking on one of the numbered tabs 2 Click on the Recall button 3 A dialog bo...

Page 32: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page 24 Revision 1 0 4 8 ALARMS ...

Page 33: ...tellite Modulators Revision 1 0 Page 25 Figure 4 8 Alarms Tab This section allows the user to monitor the status of the product and get notified if a fault has occurred Figure 4 8 shows all the parameters that are monitored under Alarms section ...

Page 34: ...0MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page 26 Revision 1 0 The GREEN indicator at the front of each alarm shows the GOOD status and it turns RED whenever a faulty situation is detected ...

Page 35: ...ade Button 2 Mark the check box beside the 7780MD 3 Click Browse to find the image needed for the upgrade The suffix should be in this format tar gz 4 Click Upgrade Figure 5 2 Selecting the 7780MD 5 The unit will reboot itself once the upgrade is finished Note Wait for the unit to reboot and show up in the tree Hitting Refresh will display the latest status 6 To verify the update and ensure the ve...

Page 36: ...7780MD Series DVB S S2 S2X L Band and IF Satellite Modulators Page 28 Revision 1 0 Figure 5 3 Verifying Firmware Upgrade ...

Reviews: