7800/7700 MultiFrame Manual
7812UDXD Series 3G/HD Up/Down/Cross Converter with Simultaneous Dual Format Outputs and AES I/O
Revision 1.1.1
Page - 177
6.50.7.4.7.
Start/Continue
The
Start/Continue
control will commence or resume the duration in which loudness values are being
used to calculate the
Integrated Loudness
measurement.
6.50.7.4.8.
Stop/Pause
The
Stop/Pause
control will terminate or pause the duration in which loudness values are being used to
calculate the
Integrated Loudness
measurement. Each time this button is activated, a new
Integrated
Loudness
value will be produced.
6.51. INTELLIGAIN
TRAPS TAB
The IntelliGain
system can provide real time analysis and confidence monitoring with SNMP trap alarm
notification. These alarms can be enabled and disabled on an individual audio program basis using the
IntelliGain
Fault Traps configuration tab.
To enable or disable an SNMP alarm notification, either check or un-check the defined control.
The system also provides real time trap status information. If a trap is sent by the IntelliGain
system,
the trap status box will change state indicating the real time value for that trap. For example, if the trap
status box is the colour green, then the trap has not been sent. However, if the status box is the colour
red, then the fault is in a current state of alarm. Once corrected, the status box will turn back to the colour
green.
IntelliGain
Traps tab identifies the VistaLINK
®
configuration view for the IntelliGain
Fault Traps.