7800/7700 MultiFrame Manual
7812UDXD Series 3G/HD Up/Down/Cross Converter with Simultaneous Dual Format Outputs and AES I/O
Revision 1.1.1
Page - 187
7.
JUMPERS
Figure 7-1 and Figure 7-2 provide the locations of the jumpers and LEDs on the 7812UDXD series
boards.
MODULE
STATUS
Run
Serial
J7
J2
Upgrade
ON
J2
OFF
FRAME
STATUS
Figure 7-1: Location of Jumpers – Top View Main Module
P
O
W
E
R
S
U
P
P
L
Y
K
E
Y
M
U
S
T
B
E
I
N
S
T
A
L
L
E
D
W
IT
H
7
7
0
0
P
S
ON
1
Figure 7-2: Location of Jumpers – Bottom View Main Module
7.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME
STATUS
FRAME STATUS:
The FRAME STATUS jumper J2 is located near the rear of the board and close to
the white metal connector. The FRAME STATUS jumper determines whether local
faults (as shown by the Local Fault indicator) will be connected to the 7700FR-C or
7800FR frame's global status bus.
To monitor faults on this module with the frame status indicators (on the PS FRAME
STATUS LED's and on the Frame's Fault Tally output) install this jumper in the On
position. (Default)
When this jumper is installed in the Off position, local faults on this module will not
be monitored.