7800 Multiframe Manual
7825DSK2-LG(-HD)(-3G) 3G/HD/SD Dual Downstream Keyer
Page 5-20
Revision 2.0
RCP OPERATION
5.6.11.
Auto Proto Debug Functions
Two automation debug functions are provided in the
GENERAL
menu. One is for the Evertz
automation protocol and is called
Automation Debug
. The other is for the M2100 automation protocol
and is called
M2100 Auto Debug
. Both work in essentially the same way. When you turn on one of
the automation debug functions, the data packets being received from the automation system are
output to the Upgrade RS-232 serial port. To view the data, use a terminal program with the following
settings: baud rate: 57600, data bits: 8, parity: none, stop bits: 2, flow control: none.
These functions are used to view the commands that are being sent by the automation system. If you
are having problems with a unit that is being controlled from automation, Evertz service personnel
may ask you to provide a capture of the data being output on the serial port when the debug function
is turned on.
GENERAL
This menu item sets the Automation Debug Protocol to M2100 Auto
Debug, XY Auto Debug or Evertz Auto Debug. Once the protocol is
selected, it can be turned either ON or OFF.
The OFF command is selected by default. To enable Debug, press the
SELECT
button and then use the
or
pushbuttons to scroll through the
options. Pressing the
SELECT
button gain will set the value.
Auto Proto Debug
M2100 Auto Debug
XY Auto Debug
Evertz Auto Debu
GENERAL
This menu item turns the EAS Debug ON or OFF.
OFF is selected by default. To enable Debug, press the
SELECT
button
and then use the
or
pushbuttons to scroll through the options.
Pressing the
SELECT
button will set the value.
EAS Debug
On
Off
GENERAL
This menu item allows the 7825DSK2 to control a Router. Under Router
Selection, there are two options; “Evertz Xenon” and “Evertz X1204”. To
select a router, press the
SELECT
button and then use the
or
pushbuttons to scroll through the options. Pressing the
SELECT
button
will set the router type.
To enable Router Control, select either ON or OFF. Press the
SELECT
button and then use the
or
pushbuttons to scroll through the options.
Pressing the
SELECT
button will set the value.
Router Setup
Router Selection
Router Enable
GENERAL
This menu item sets the Automation Debug Protocol to M2100 Auto
Debug, XY Auto Debug or Evertz Auto Debug. Once the protocol is
selected, it can be turned either ON or OFF.
The OFF command is selected by default. To enable Debug, press the
SELECT
button and then use the
or
pushbuttons to scroll through the
options. Pressing the
SELECT
button gain will set the value.
Video Input
Mandatory
Input A
Input B
Input Key_1
Input Fill_1
Input Key_2
Input Fill_2