7800 Multiframe Manual
7825DSK2-LG(-HD)(-3G) 3G/HD/SD Dual Downstream Keyer
Page 4-18
Revision 2.0
VLPRO OPERATION
4.8.2.3.
Configuring the Load Preset Function
The
Load Preset
option is used to select the preset that will be loaded when the GPI input is closed to
ground. The following items are available in the drop down menu:
NONE:
If you do
not
want to load a user preset when the GPI is closed, select the
NONE
item. If
NONE
is selected then the existing settings will be used.
1 to 10:
Select
1
to
10
to load a specific user preset when the GPI is closed.
4.8.2.4.
Configuring the Action
The
Action
option is used to select the action that will occur when the GPI input is closed to ground.
The following items are available in the drop down menu:
NONE:
If you do not wish to perform any action, select
NONE
.
CUE:
Select
CUE
to load the logo selected by the
CLogo
menu item into memory.
The logo will not be displayed by this action.
IN:
Select
IN
to load the logo selected by the
CLogo
menu item into memory and
fade it in.
OUT:
Select
OUT
to fade out the logo selected by the
CLogo
menu item.
TOGGLE:
Select
TOGGLE
when the GPI is closed.
DUCK IN:
Select
DUCK IN
to begin a ‘Duck Audio Insert’.
DUCK OUT:
Select
DUCK OUT
to end a ‘Duck Audio Insert’.
DUCK:
Select
DUCK
to toggle the state of the 'Duck Audio Insert'. If a 'Duck Audio
Insert' is in effect it will be stopped or if a 'Duck Audio Insert' is not in effect it will
be started. This function is useful if you want to use a momentary contact
closure as opposed to a maintained contact closure to trigger a voice-over, but
the disadvantage is that the current state of the voice-over is not guaranteed.
ALL OUT:
Select
ALL OUT
to fade out all logos.
TIMER1 or TIMER2:
Select
TIMER1
or
TIMER2
to initiate a count up or count down function
for a time logo.
4.8.2.5.
Configuring the Logo Function
The
Logo
option is used to select a logo to be acted on if the “Closed Action” item is set to
CUE, IN
or
OUT
.
NONE:
Select
NONE
to disable any logo actions.