7882DEC-H264HD-IPASI
HD/SD MPEG-2 and H.264 Decoder
Page - 48
Revision 1.0
WEBEASY
5.11. FAULTS
7882DEC-H264HD-IPASI has a Fault Page where the following information can have traps set and will
display if there is a fault present. Red indicates there is a fault present and green indicates there is no
fault present.
Figure 5-14: : WebEASY
®
– Faults Tab
CC Fault Present
Video CC Error:
This control checks whether a continuity counter fault is currently present.
Audio 1-4 CC Error:
This control checks whether a continuity counter fault is currently present.
Memory Self Test Fault Present
Memory Self Test:
This control checks whether a memory self test fault is currently present.
Input Fault Present
TS Input Missing:
This control checks whether an input fault is currently present.
TS Sync Byte Missing:
This control checks whether a TS Sync Byte is missing.
Input Bit Error:
This control is used to enable and disable input traps.
SCTE 35 Data Present:
This control is used to enable and disable input traps.
SCTE 104 Data Inserted:
This control is used to enable and disable input traps.