Input Program Control
Program Tuning Mode:
Options are Auto PID Select or Manual PID Select.
o
Selection of
Auto PID Select
will set the decoder to decode either the
First Program In The PAT
Lowest Program Number
Specific Program Select
Specific Service Name
o
Manual PID Select
allows the user to define the
Manual PID Control
section.
Video PID Select
PCR PID Select
VANC PID Select
Auto Program Select Mode:
Options are First Program in PAT or Lowest Program Number.
o
First program indicates the first program defined within the PAT.
o
Lowest program number will select the program with the lowest Program ID.
o
Specific Program Select
Program Number Select:
This control is used to specify the program number for decoding; only
applicable in auto mode.
When the Program Tuning mode is set to Auto PID Select and Auto Program Select is set to Specific
Program Select, the Program Number and View list will be available to make your selections. Enter in
the program number manually or use the View List drop down menu to make your selection.
Manual PID Control
When Program Tuning Mode is set to Manual PID Select, then these values will be applied.
Video PID Select (2 – 8190):
This control is used to specify the video PID for decoding.
PCR PID Select (2 – 8190):
This control is used to specify the PCR PID for decoding.
VANC PID Select (2 – 8190):
This control is used to specify the VANC PID for decoding.
Input Profile
For Main and Backup:
Input Source Select:
This control is used to select the physical input source for the Decoder. Options
are Data 1, Data 2, ASI 1 or ASI 2.
IP Address:
This control is used to specify the multicast address to be received.
UDP Port Number:
This control is used to specify the associated UDP port number for the multicast.
Initial IGMP Version:
This control is used to specify the initial IGMP version to use. Options are V2 or
V3.
IGMPV3 Mode: