7890MG Series
Universal Media over IP Gateway for 10 x ASI/SD/HD/3G/GE
Page - 26
Revision 0.2
VISTALINK
®
PRO
4.11. TRUNK FAULT TAB
Figure 4-11: VistaLINK
®
PRO - Trunk Fault Tab
Trunk Select:
Brings up the Trunk Fault SNMP Error Traps for Trunk A and Trunk B. The check
boxes on the left will enable or disable these faults from being sent to the SNMP Fault Trap log.
Traps
Trunk Error:
Triggers whenever errored seconds appear on the selected Trunk Interface.
Trunk Severe Error:
Triggers whenever severe errored seconds appear on the selected Trunk
Interface.
Trunk Link Down:
Triggers when the trunk link is not active.
Trunk Bandwidth Higher:
Trunk bandwidth is greater than max bandwidth threshold set in Trunk
Port TAB
Bandwidth High Threshold.
Trunk Bandwidth Lower:
Trunk bandwidth is less than min bandwidth threshold set in Trunk Port
TAB -> Bandwidth Low Threshold.