Model 8010TM SDI Time Code Master Manual
Page 3-20
Revision 1.5.1
OPERATION
3.5.
READER FUNCTIONS
3.5.1. Setting the Active Reader – Reader Assignment
RDR ASSIGNMENT
The
RDR ASSIGNMENT
menu is used to select whether the LTC or
VITC reader will be used in the momentary and continuous Jam Sync
modes. The reader that is active will be shown in brackets e.g. (ltc) the
front panel display. The reader data from the inactive reader will still be
visible from the front panel and VCG windows but will have no effect on
the generator time in the jam sync modes, or user bits in the user bit
transfer modes.
Select
Rass (ltc) vitc
to configure the Linear Time Code (LTC) as the
active reader.
Select
Rass ltc (vitc)
to configure the Vertical Interval Time Code
(VITC) as the active reader.
Select
Rass auto
to configure the reader to automatically switch
between Linear Time Code (LTC) and Vertical Interval Time Code
(VITC) reading. In this auto reader mode the LTC and VITC readers
have equal priority. The current active reader will continue reading as
long as there is a valid input present. The current active reader will be
shown in brackets.
Select
Rass lauto
to configure the reader to automatically switch
between Linear Time Code (LTC) and Vertical Interval Time Code
(VITC) reading. In this auto reader mode the LTC reader has priority
and will be used as the active reader whenever there is valid LTC
present. The current active reader will be shown in brackets.
Select
Rass vauto
to configure the reader to automatically switch
between Linear Time Code (LTC) and Vertical Interval Time Code
(VITC) reading. In this auto reader mode the VITC reader has priority
and will be used as the active reader whenever there is valid VITC
present. The current active reader will be shown in brackets.
Rass (ltc) vitc
Rass ltc (vitc)
Rass auto (ltc)
Rass lauto (ltc)
Rass vauto(vitc)
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...