OPERATION
3.5.4. Configuring Whether the LTC Reader will Display Local Time
or UTC Time in Time/Date Mode
LTC RDR TZ ADJ
When the
LTC RDR MODE
is set to
TIME DATE
, the
LTC RDR TZ ADJ
menu item is used to select whether the LTC Reader will display UTC
or UTC adjusted by the programmed Time Zone Offset (Local Time).
The local time will also be adjusted by the daylight savings time
adjustment if daylight savings time is in effect. See section 3.4.8 for a
discussion of daylight saving time features of the 8010TM.
Select
Ltm zone adj utc
to configure the reader to output its time as
UTC.
Select
Ltm zone adj loc
to configure the reader to output its time as
UTC adjusted by the programmed Time Zone Offset and Daylight
saving adjustment if
DST Time is On
. (Local Time)
Ltm zone adj utc
Ltm zone adj loc
3.5.5. Selecting the Format of the VITC Reader Time and User Bit Data
VITC RDR MODE
The
VITC RDR MODE
menu item is used to select the type of
information that is contained in the time and user bits of the VITC
reader.
Select
VR mode time data
when the time bits contain normal time
information and the user bits contain numeric data.
Select
VR mode time time
when both the time and the user bits contain
time information.
Select
VR mode time date
when the time bits contain time information
and the user bits contain date information. The
VITC RDR TZ ADJ
menu item controls whether local time or UTC will be displayed.
Select
VR mode data data
when both the time and the user bits contain
numeric data.
VR mode time data
VR mode time rtime
VR mode time date
VR mode data data
3.5.6. Setting the VITC Reader Line Range
VITC RDR START
The
VITC RDR START
and
VITC RDR END
menu items are used to
select the lines that are enabled for VITC reading. VITC reading is
enabled between the lower and higher line numbers shown (inclusive).
When the
VITC RDR START
menu item is first selected, the starting
line number for the VITC reader will be shown. Press the left and right
(
,
) keys to change the starting line. Press the down (
) key to
select the
VITC RDR END
menu item. Press the left and right (
,
)
keys to change ending line.
Start line = xx
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...