Model 8010TM SDI Time Code Master Manual
OPERATION
Revision 1.5.1
Page 3-23
3.5.7. Controlling the VITC Reader ‘Look Ahead’ Compensation
VITC RDR DISPLAY
The
VITC RDR DISPLAY
menu item is used to select whether the
normal 'look ahead' compensation for VITC reader dropouts is active or
not. Normally, the data is read in one field and displayed with an 'add 1
field' compensation. In some operational modes it is desirable to
disable this feature and to display exactly what is being read. The
topmost positions of the character generator are not available when in
the direct mode.
Select
VR disp direct
to enable
DIRECT
display mode. Data is
displayed exactly as it is read without 'look ahead' compensation.
Displays from the VITC reader will be 1 field late and cannot be
positioned at the very top of the raster.
DIRECT
mode is usually used
for diagnostic purposes only.
Select
VR disp process
to enable normal 'look ahead' compensation.
Displays from VITC reader will be 'on time' but will
NOT
follow code
discontinuities immediately.
PROCESSED
mode should be used for
normal operations.
VR disp process
VR disp direct
3.5.8. Configuring Whether the VITC Reader will Display Local Time
or UTC Time in Time/Date Mode
VITC RDR TZ ADJ
When the
VITC RDR MODE
is set to
TIME DATE
, the
VITC RDR TZ ADJ
menu item is used to select whether the VITC
Reader will display UTC or UTC adjusted by the programmed Time
Zone Offset (Local Time). The local time will also be adjusted by the
daylight savings time adjustment if daylight savings time is in effect.
See section 3.4.8 for a discussion of daylight saving time features of
the 8010TM.
Select
Vtm zone adj utc
to configure the generator to output its time as
UTC.
Select
Vtm zone adj loc
to configure the generator to output its time as
UTC adjusted by the programmed Time Zone Offset and Daylight
saving adjustment if
DST Time is On
. (Local Time)
Vtm zone adj utc
Vtm zone adj loc
3.6.
CHARACTER GENERATOR FUNCTIONS
The 8010TM has six independently positionable character windows to display the generator and LTC
and VITC reader time and user bits. The four arrow keys (
,
,
,
) control the position of all the
windows. The
CHAR GEN ON/OFF
key selects whether the video character generator (VCG) keyer is
on or off. The use of these keys in combination with the
CHAR GEN WINDOW
key selects which
windows are displayed and their position on the screen.
Five items on the programming menu are used to configure the character size, style, and whether
frames, fields and symbols should be displayed in the character generator. The following descriptions
appear in the order they appear on the menu.
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...