3.7.4. Selecting the Generator Date Format for Time Date Mode
GEN DATE FORMAT
The
GEN DATE FORMAT
menu item is used to set the encoding
format when date information is being placed into the user bits.
Selecting
yymmdd
configures the user bits for BCD date encoding in
TT YY MM DD format according to SMPTE 309M. This mode is
designed so that simple time code readers can display the BCD
encoded date information in numeric format.
TT
is a time zone offset to be applied to the Hours of the time
YY
is the year in BCD format.
•
When
YY
is less than 50 the year will be displayed as 20YY
(i.e.: when
YY
=01 the year will be displayed as 2001).
•
When
YY
is greater than 50 the year will be displayed as 19YY
(i.e.: when
YY
=95 the year will be displayed as 1995).
MM
is the month of the year.
DD
is the day of the month.
For example: the date August 15, 1994 (no time zone offset) will be
encoded in the user bits as 00 94 08 15.
Selecting
mjd
configures the user bits for modified Julian date encoding
in TT dddddd format according to SMPTE 309M. This mode should be
used when the complete date including century is required. Simple
readers will not be able to decode this format.
TT
is a time zone offset to be applied to the Hours of the time
ddddd
is a 24 bit binary number representing the modified Julian
date.
Selecting
leitch
configures the user bits for date encoding in Leitch
Master Clock format. This mode should be used when driving Leitch
compatible display devices. Simple readers will not be able to decode
this date format.
Gen date yymmdd
Gen date mjd
Gen date leitch
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...