Model 8010TM SDI Time Code Master Manual
Page 3-36
Revision 1.5.1
OPERATION
3.7.12.1. Setting the SDI Vertical Interval Blanking
SDI VBLANK END
The
SDI VBLANK END
menu item is used to determine where the V bit
in the SDI TRS will be set to zero (indicating vertical blanking). If the V
blank bit is zero on a higher line number than the VITC is placed on,
some devices may discard the VITC.
For 525 systems the normal setting is for the vertical blanking to end at
line 10. If this causes problems with downstream devices, it can be set
to end at line 20; however some devices may blank the VITC if it is
placed prior to line 20.
For 625 systems, the normal setting is for the vertical interval to end at
line 6. If this causes problems with downstream devices, it can be set
to end at line 23, however some devices may blank the VITC if it is
placed prior to line 20.
Vbl end line 06
Vbl end line 23
Vbl end line 10
Vbl end line 20
3.7.13. Setting the NTSC Setup Pedestal on the Monitor Analog Output
NTSC SETUP
The
NTSC SETUP
menu item is used to determine how the NTSC
Setup Pedestal will be applied on the Monitor Analog Output. The
NTSC setup pedestal should not be present when operating in Japan.
Select
NTSC setup on
to apply the Setup pedestal to all lines of the
active picture.
Select
NTSC setup off
to remove
the NTSC Setup Pedestal from all
lines.
NTSC setup on
NTSC setup off
No setup in PAL
3.7.14. Downloading New Character Fonts
FONT DOWNLOAD
The
FONT DOWNLOAD
menu item is used to change the character
inserter font. For more information about uploading new font files see
section 5.4.
Shift+sel=start
3.7.15. Resetting the 8010TM to Factory Defaults
FACTORY RESET
The
FACTORY RESET
menu item is used to return the 8010TM to its
factory defaults. When you press the
or
keys, the display shows
Shift+sel=reset. When you press
SHIFT + SELECT
the 8010TM will
reload its factory defaults and show the message:
Reset done
Shift+sel=reset
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...