Model 8010TM SDI Time Code Master Manual
OPERATION
Revision 1.5.1
Page 3-21
3.5.2. Configuring the Selecting the Format of the LTC Reader Time and User Bit Data
LTC RDR MODE
The
LTC RDR MODE
menu item is used to select the type of
information that is contained in the time and user bits of the LTC
reader.
Select
LR mode time data
when the time bits contain normal time
information and the user bits contain numeric data.
Select
LR mode time time
when both the time and the user bits contain
time information.
Select
LR mode time date
when the time bits contain time information
and the user bits contain date information. The
LTC RDR TZ ADJ
menu item controls whether local time or UTC will be displayed.
Select
LR mode data data
when both the time and the user bits contain
numeric data.
LR mode time data
LR mode time rtime
LR mode time date
LR mode data data
3.5.3. Controlling the LTC Reader ‘Look Ahead’ Compensation
LTC RDR DISPLAY
The
LTC RDR DISPLAY
menu item is used to select whether the
normal 'look ahead' compensation for LTC reader dropouts is active or
not. Normally, the data is read in one frame and displayed with an 'add
1 frame' compensation. In some operational modes it is desirable to
disable this feature and to display exactly what is being read. The
topmost positions of the character generator are not available when in
the direct mode.
Select
LR disp direct
to enable
DIRECT
display mode. Data is
displayed exactly as it is read without 'look ahead' compensation.
Displays from the LTC reader will be 1 frame late and cannot be
positioned at the very top of the raster.
DIRECT
mode is usually used
for diagnostic purposes only.
Select
LR disp process
to enable normal 'look ahead' compensation.
Displays from LTC reader will be 'on time' but will
NOT
follow code
discontinuities immediately.
PROCESSED
mode should be used for
normal operations.
LR disp process
LR disp direct
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...