INSTALLATION
Pin
#
Name Description
1
GPI 01
General Purpose Input 01
2
GPI 02
General Purpose Input 02
3
GPI 03
General Purpose Input 03
4
GPI 04
General Purpose Input 04
5
GPI 05
General Purpose Input 05
6
GPI 06
General Purpose Input 06
7
Tx+
RS-422 Tx+(b) Output
8
Tx-
RS-422 Tx-(a) Output
9
GND
Serial I/O Ground
10
Rx+
RS-422 Rx+(b) Input
11
Rx-
RS-422 Rx-(a) Input
12
SELECT
RS-422/232 Select (Gnd for RS232)
13
GPI 07
General Purpose Input 07
14
GPI 08
General Purpose Input 08
15
Vext
External voltage input to power opto isolators
16
Vint
Pro5 volts output from unit
17
GPO 01 NC
General Purpose Output 01 Normally closed contact
18
GPO 01 C
General Purpose Output 01 Common contact
19
GPO 02 NC
General Purpose Output 02 Normally closed contact
20
GPO 02 C General Purpose Output 02 Common contact
21
GPO 03 NC
General Purpose Output 03 Normally closed contact
22
GPO 03 C General Purpose Output 03 Common contact
23
GPO 04 NC
General Purpose Output 04 Normally closed contact
24
GPO 04 C
General Purpose Output 04 Common contact
25
GND
Unit Chassis ground
Table 2-2: GPI/O Port Pin Definitions
2.1.6. Power
Connections
The main unit has one or two universal voltage power supplies that operate on 100 to 240 Volts 50/60 Hz
AC.
2.2. MOUNTING
The HDSD9545DLY-PRO is equipped with rack mounting angles and fits into a standard 19 inches by 3.5
inches (483 mm x 89 mm) rack space. The mounting angles may be removed if rack mounting is not
desired.
2.3. POWER
REQUIREMENTS
Power requirements are 100 to 240 volts AC at 50 or 60 Hz. The HDSD9545DLY-PRO has universal
power supplies that automatically sense the input voltage. Power should be applied by connecting a 3-
wire grounding type power supply cord to the power entry module on the rear panel. The power cord
should be minimum 18 AWG wire size; type SVT marked VW-1, maximum 2.5 m in length. If the units are
fitted with the redundant power supply there will be an additional IEC-320 connector on the rear panel.
The power entry module combines a standard power inlet connector, two 5 x 20 mm fuse holders and an