HDSD9545DLY - PRO Profanity Bypass Delay Manual
Page 4-10
Revision
1.3.7
TECHNICAL DESCRIPTION
For Example:
UPLOAD OKAY
PPC BOOT
> |
13. The following is a list of possible reasons for a failed upload:
•
If you get the message "transfer cancelled by remote" you must restart the terminal program and
load the bin file, then remove and install the module again.
•
The supplied “*.bin” file is corrupt.
•
Wrong file specified to be uploaded.
•
Wrong file transfer protocol used – make sure you specify Xmodem, not Xmodem 1K.
•
The PCs’ RS-232 communications port cannot handle a port speed of 57600.
•
Noise induced into the Serial Upgrade cable.
4.3.2.4.
Step 4 – Completing the Upgrade
14. Power cycle the unit. It should proceed through a normal boot up sequence.
15. You can now close the terminal program and disconnect the RS-232 serial cable from the PC and the
unit.
Summary of Contents for HDSD9545DLY-PRO
Page 2: ......