When connecting two X0401 series routers together in a master/slave relationship make sure that the
REMOTE CTL
port is configured the same at both ends (including the RS232 or RS422 wiring). Use the
cable shown in Table 2-6 for RS-232 wiring and the cable shown in Table 2-7 for RS-422 wiring. The user
can also order a 5600 syncro cable (approx. 1 foot in length) or a 9600-SW-I-0 cable (approx. 5 feet in
length) to interconnect two routers with RS-232 wiring. For other applications, consult the manual for the
equipment that you are connecting, configure the port accordingly and use the information in Table 2-1 to
make an appropriate cable.
Master 0401 End
Slave 0401 End
9 pin D
Male
Pin
Belden
9729
9 pin D
Male
Pin
1
1
TxD
2
-------2b------
RxD
3
RxD
3
-------1a------
TxD
2
4
4
Gnd
5
---drain 2----
Gnd
5
6
6
RTS
7
-------1b-----
CTS
8
CTS
8
-------2a------
RTS
7
9
9
Frame Gnd
Shield ---drain 1----
Frame Gnd
Shield
Table 2-6: Master 0401 to Slave 0401 Cable – RS-232 Configuration
Master 0401 End
Slave 0401 End
9 pin D
Male
Pin
Belden
9729
9 pin D
Male
Pin
Gnd
1
---drain 2----
Gnd
1
Tx-/TxD
2
-------2b------
Rx-/RxD
8
Rx+/RxD
3
-------1a------
Tx+/TxD
7
RxGnd
4
RxGnd
4
5
5
TxGnd
6
TcGnd
6
Tx+/RTS
7
-------1b-----
Rx+/CTS
3
Rx-/CTS
8
-------2a------
Tx-/RTS
2
9
9
Frame Gnd
Shield ---drain 1----
Frame Gnd
Shield
Table 2-7: Master 0401 to Slave 0401 Cable – RS-422 Configuration
2.7.
CONTROLLING THE ROUTER USING VISTALINK
®
X0401H Series routers fitted with the “+ET” option have a 10Base-T or 100Base-TX Ethernet port, which
is used as a point of access to communicate with VistaLINK
®
for crosspoint routing through the use of
Simple Network Management Protocol. (At the time of writing this option is only available on the X0401H-
AES4-HES version.) These routers are designed to be used with either 10Base-T (10 Mbps) or 100Base-
TX (100 Mbps) also known as
Fast Ethernet
, twisted pair Ethernet cabling systems. When connecting for
10Base-T systems, category 3, 4, or 5 UTP cable as well as EIA/TIA – 568 100
Ω
STP cable may be used.
Summary of Contents for X0400 Series
Page 2: ...This page left intentionally blank ...
Page 6: ...X0400 Series Router Manual Revision 1 4 4 REVISION HISTORY This page left intentionally blank ...
Page 14: ...X0400 Series Router Manual Revision 1 4 4 OVERVIEW This page left intentionally blank ...
Page 42: ...X0400 Series Router Manual Revision 1 4 4 OPERATION This page left intentionally blank ...
Page 90: ...X0400 Series Router Manual Revision 1 4 4 SERIAL CONTROL This page left intentionally blank ...