3.14.3. Selecting the Serial Control Address
REMOTE CTL
The GVG Ten XL protocol allows multiple devices to be addressed. The
Serial Address
menu item is used to set a unique address for each router
that is connected. When the X0401 series router is operating in the
master
mode, it will send out commands to the router that matches its
serial
address
. When the X0401 series router is operating in
slave
mode, it will
only respond to commands that match its
serial address.
If two X0401 series
routers are connected in a master/slave configuration, then the address of
both routers must be set the same (only 1 video buss on the X0401).
Use the
↑
and
↓
arrows to select the desired address and press the
SELECT
key to confirm the new address.
The
Baud Rate, Serial Format
and
Serial Control
settings must also be set to
match the desired control protocol.
Serial Address
address = 1
valid address
values are
1 to 64
3.14.4. Selecting the Serial Data Control Mode
REMOTE CTL
This menu item is used to select the router, which will issue commands or
respond to commands on the Remote Control port.
When set to
slave
, the router will respond to commands it receives on the
control port.
When set to
master
, the router will issue commands using the currently
selected protocol.
In master mode three items are displayed:
1. When the master gets a response back from the slave and it does not
match the masters crosspoint setting, it will display "
Error: Mismatch
".
2. When the response from the slave matches the crosspoint setting of the
master, and if the power supply status in response is set to 0xff, it will
display
REM: V: # A: # PS:xx
(where # is the crosspoint setting of video
and audio).
3. When the response from the slave matches the crosspoint setting of the
master, and if the power supply status in response is set to anything other
than 0xff, it will display
REM: V: # A: # PS: ## (
where # is the crosspoint
setting of video and audio, and ## is the actual power supply status value
that the master got in response from the slave).
The
Baud Rate, Serial Format,
and
Serial Address
settings must also be set
to match the desired control protocol.
Serial Control
slave
master
Summary of Contents for X0400 Series
Page 2: ...This page left intentionally blank ...
Page 6: ...X0400 Series Router Manual Revision 1 4 4 REVISION HISTORY This page left intentionally blank ...
Page 14: ...X0400 Series Router Manual Revision 1 4 4 OVERVIEW This page left intentionally blank ...
Page 42: ...X0400 Series Router Manual Revision 1 4 4 OPERATION This page left intentionally blank ...
Page 90: ...X0400 Series Router Manual Revision 1 4 4 SERIAL CONTROL This page left intentionally blank ...