4.4.2. Step 2 – Download the Current Labels from the Router
6. Invoke the
Label Send File
mode using the front panel Setup Menu. (See section 3.4 for information on
how to operate the front panel menus.)
•
Press the
SETUP
button once to enter the front panel menu.
•
Press the
↑
&
↓
keys until the front panel display reads
INPUT LABEL.
•
Press the
SELECT
button.
•
Press the
↑
&
↓
keys until the front panel display reads
Input Label File.
•
Press the
SELECT
button.
•
Press the
↑
&
↓
keys until the front panel display reads
Send file?
•
Press the
SELECT
button twice to send the file to the terminal program.
7. When you have captured the file, you will need to close the capture file.
If you are using HyperTerminal
this is executed using the
Transfer/Capture Text
menu item again.
4.4.3. Step 3 – Editing the Label Text File
8. Using a text editor such as Notepad, edit the input labels in the file you have captured.
Note: It is not recommended that you use a word processor such as
Microsoft Word, as it may append hidden control codes into the text file,
which will not allow the edited file to be uploaded correctly to the router.
The file structure is as follows:
[category_a]<CR><LF>
labelvar_a1=value 1<CR><LF>
labelvar_a3=value 2<CR><LF>
labelvar_a2=value 3<CR><LF>
[category_b]<CR><LF>
labelvar_b1=value<CR><LF>
labelvar_b2=value<CR><LF>
<CR><LF>
<CR><LF>
<CR><LF>
Note: <CR><LF> = Enter key
Each category is enclosed in square brackets [] and identifies the input category (e.g.
[VIDEO],
[AUDIO1A]
) for a group of associated label variables. The label variables must follow their associated
category in the file and represent the label names that can be changed in the router. The value that
follows the equals sign is a 16 character maximum length text string that is assigned to the variable.
Alphanumeric characters such as a-z, A-Z, 0-9 and punctuation (ISO Character values 32 to 126) are
valid. Label variables can be in any order as long as they occur in the correct category section of the
file. Physical inputs on the router that do not have an associated label variable will retain their original
value when the label file is uploaded to the router. If a label variable is specified more than once, the
last value in the file will be used.
Summary of Contents for X0400 Series
Page 2: ...This page left intentionally blank ...
Page 6: ...X0400 Series Router Manual Revision 1 4 4 REVISION HISTORY This page left intentionally blank ...
Page 14: ...X0400 Series Router Manual Revision 1 4 4 OVERVIEW This page left intentionally blank ...
Page 42: ...X0400 Series Router Manual Revision 1 4 4 OPERATION This page left intentionally blank ...
Page 90: ...X0400 Series Router Manual Revision 1 4 4 SERIAL CONTROL This page left intentionally blank ...