SAFETY INSTRUCTIONS 

 

THESE  INSTRUCTIONS  ARE  INTENDED  TO  PROVIDE  SAFE,  TROUBLE-FREE  SERVICE  FROM  YOUR 
STAPLER.  READ  THEM  CAREFULLY.  OPERATORS  SHOULD  WEAR  SAFETY  GLASSES  OR  GOGGLES 
WHEN  OPERATING  THIS  TOOL.  WHEN  THE  AIR  SUPPLY  IS  CONNECTED  KEEP  YOUR  HANDS  AND 
BODY  AWAY  FROM  THE  FASTENER  DISCHARGE  AREA.  ALWAYS  DISCONNECT  THE  AIR  SUPPLY 
BEFORE MAKING ADJUSTMENTS, OR SERVICING THE TOOL. 

A reasonable amount of care will prevent damage to vital working parts and increase the life of the tool. Do not 
abuse this tool. A moderate amount of care will give long efficient service. 

AIR SUPPLY AND CONNECTIONS 

Clean dry air is vital. Air operated tools and equipment need clean, dry, lubricated air for top performance, low 
maintenance, and long service. The major cause of failure in air operated equipment is dirty, moist, improperly 
lubricated air. Failure appears as a slow, continuous deterioration of the tool. Dirt, grit and pipe scale generally 
present in air line can cause severe abrasive wear in valves and cylinder walls. A filter-Regulator-Lubricator unit 
is  essential  and  should  be  installed  as  close  to  the  tool

 

as  possible:  preferably  within  15  feet  (4.6  meters). 

Periodic checks should be made to insure the unit is working properly. A dirty filter will result in pressure loss. As 
dirt accumulates in the filter, the pressure drop increases resulting in lower pressure at the tool and less efficient 
fastener driving. Fill the lubricator with Air Tool Lubricant, Mobil Velocite #10, or equivalent. Do not use a detergent 
oil.

 

The  air  supply  must  be  capable  of  maintaining  an  air  pressure  of  50-80  pounds  (3.4  -  5.5  atmospheres)  per 
square inch at the tool. 

OPERATING PRESSURE MUST NOT EXCEED 100 PSIG (6.8 atmospheres).

 Check 

the air hose or pipe before attaching it to the filter unit to be sure it is clean. 

DO NOT CONNECT FEMALE QUICK COUPLER DIRECT TO TOOL. ATTACH MALE FREE FLOW NIPPLE 
TO  TOOL,  AND  FEMALE  QUICK  COUPLER  TO  AIR  HOSE.  IF  CONNECTED  IMPROPERLY  AND 
DISCONNECTED  FROM  AIR  SUPPLY  TOOL  WILL  REMAIN  CHARGED  WITH  AIR,  WILL  NOT  FREELY 
EXHAUST AND WILL DRIVE A FASTENER IF TRIGGER MECHANISM IS ACTUATED. 

All hoses, pipes and fittings must have a 3.8” (9.5mm) minimum inside diameter. Hose fittings must have a 9/32” 
(7.1mm) minimum inside diameter. Air requirements will vary with the type of material to be fastened, and the 
operating speed. Do not use more air pressure than required for the job. Air pressure in excess of the amount 
required to provide adequate fastening, wastes compressed air and may result in damage to equipment. 

For best results the air pressure can be determined by driving a few fasteners into the work and adjusting the air 
pressure until the staple crown is driven down to the work. Excessive air pressure may cause the staple crown to 
cut the material. 

After  all  air  connections  are  made,  check  to  be  sure  they  are  tight  to  prevent  air  loss,  and  insure  best 
performance. 

 

FASTENER LOADING 

 

Pull cover back until locked by detent pin. Insert stick of fasteners and push forward into channel. Then push cover 

forward until locked by detent pin. The tool is now ready to operate. 

 

OPERATION 

Do not attempt to operate the tool without fasteners, or drive fasteners into the air, as the life of the tool will be 
reduced, plus the danger involved by driving fasteners into the air. Hold the tool with a firm grip on the rubber 
handle, and on cylinder assembly below the valve housing. Place the tool over the location where the fastener is 
required and pull the trigger. 

ALWAYS LOAD WITH NOSE POINTING AWAY FROM YOU.   

Summary of Contents for ECAR-S

Page 1: ...NANCE MANUAL CE DECLARATION OF CONFORMITY 20 8 19 Everwin Pneumatic Corp BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INS...

Page 2: ...enance should be read carefully and the manuals kept for reference NOTE Additional safety measures may be required because of your particular application of the tool Contact your EVERWIN representativ...

Page 3: ...eals driver blades bumpers pistons and piston rings B Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenanc...

Page 4: ...ESPAGNOL EVERWIN PNEUMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelse...

Page 5: ...inute at 80 psi 5 6 kg cm2 Take the actual rate at which the tool will be run to determine the amount of air required For instance if your fastener usage averages 30 nails per minute you need 50 of th...

Page 6: ...ESSURE MUST NOT EXCEED 100 PSIG 6 8 atmospheres Check the air hose or pipe before attaching it to the filter unit to be sure it is clean DO NOT CONNECT FEMALE QUICK COUPLER DIRECT TO TOOL ATTACH MALE...

Page 7: ...ston plug and O rings Omission of these parts will result in serious damage or air leakage LUBRICATION Use Air Tool Lubricant Mobil Velocite 10 or equivalent for all normal conditions Do not use deter...

Reviews: