 Combination of the base and the stage 

BH2-SH 

(Horizontal knob stage)

SZH-SC 

(Cup stage)

SZH-SG 

(Gliding stage)

SZX-STAD1 
(BX stage adapter type 1)

SZH-STAD1 
(Stage adapter type 1)

SZX2-ILLTS 
(Single position LED transmitted 
light illumination base)

SZX2-ILLTSA 

(High stability adapter for ILLT

)

SZX2-STADM 
(STAD mount for ILLT

)

SZX2-ILLTQ 
(Quad position LED  
transmitted light illumination base)

Illumination 

cartridge

SZX2-CBF 
SZX2-CBFH 
SZX2-CBFL 
SZX2-COB 
SZX2-COBH 
SZX2-COBL 
SZX2-CDF 
SZX2-CSH 
SZX2-CPO

U-SRP 

(Rotational stage)

U-SRG2 

(Rotational stage)

Stage

Summary of Contents for Olympus SZX2-ILLTQ

Page 1: ...nd that you study this manual thoroughly before operating this product and always keep this manual at hand when operating this product Retain this instruction manual in an easily accessible place near...

Page 2: ...arty responsible for compliance could void the user s authority to operate the product FCC Supplier s Declaration of Conformity Hereby declares that the product Product name Optical Microscope Accesso...

Page 3: ...umination 11 4 Adjusting for polarization observation 12 5 Using SZX2 CSH Shade plate cartridge 12 6 List of objectives applicable to each illumination cartridges 13 4 Troubleshooting 15 5 Specificati...

Page 4: ......

Page 5: ...erating procedure Loosen the clamping screw A using the screwdriver Remove the product B TIP NOTE CAUTION B A The following symbols are used in this instruction manual WARNING Indicates a potentially...

Page 6: ...o used in combination as a system refer to the instruction manual for the system product to be combined Intended use This product is a LED transmitted light illumination base used with SZX16 SZX10 SZX...

Page 7: ...ng Remove all attached items from SZX2 ILLTQ Quad position LED transmitted light illumination base or SZX2 ILLTS Single position LED transmitted light illumination base and reduce the weight before ho...

Page 8: ...nded our intended electric safety and EMC performance of the product cannot be assured Do not use the product in close proximity to the sources of strong electromagnetic radiation Proper operation may...

Page 9: ...eesaw type is the type of switch that ON or OFF is selected by pressing it to ON or OFF side Indicates that the seesaw type main switch is OFF Label position and instruction The labels are attached to...

Page 10: ...ronments see 5 Specifications P 16 For products optional attachable to this product see page 8 The use of this product in combination with other separately available items not only creates the risk of...

Page 11: ...y wiping moisten a soft cloth with diluted neutral detergent and wipe the dirty surface with it Do not use organic solvents because they may deteriorate the coated surface or plastic parts The stage s...

Page 12: ...e 1 SZX2 ILLTS Single position LED transmitted light illumination base SZX2 ILLTSA High stability adapter for ILLT SZX2 STADM STAD mount for ILLT SZX2 ILLTQ Quad position LED transmitted light illumin...

Page 13: ...ess control knob P 11 Main switch P 11 ON OFF Illumination selection turret P 11 This section describes the nomenclature of main operating portions that composes the product If the assembly is not com...

Page 14: ...mination base SZX2 ILLTS Oblique illumination control knob P 11 Brightness control knob P 11 Main switch P 11 ON OFF Column Stage glass with frame Reserve screw holes 4 pcs Diameter M4 depth 5 mm Rese...

Page 15: ...e the illumination cartridge see page 20 1 You can select the best illumination method by changing the illumination cartridge according to the sample For compatible cartridges see page 18 This section...

Page 16: ...sample 1 2 3 TIP 4 Adjusting for polarization observation 5 Using SZX2 CSH Shade plate cartridge The transmitted simple polarization observation is available by combining SZX2 AN Analyzer You can chec...

Page 17: ...an 2 5X less than 1 25X less than 0 8X SZX2 CPO less than 2 5X less than 1 25X less than 0 8X None less than 1 25X less than 0 8X SZX10 Research high class stereo microscope Objective Illumination car...

Page 18: ...25X less than 2X SZX2 CPO less than 1 25X less than 2X None less than 1 25X less than 1 6X MVX10 Research high class stereo microscope Objective Illumination cartridge MVPLAPO 2XC SZX2 CBFL less than...

Page 19: ...on is not appropriate Attach the cartridge to the appropriate position 20 The dust dirt is noticeable in the field of view The stage glass is dirty Clean the stage glass sufficiently 7 4 4Troubleshoot...

Page 20: ...able photo sheet filter 75 x 75 mm Up to two filters with the thickness of 0 1 mm or less Power supply Use AC adapter optional Input 100 240 V 50 60 Hz 1 2 A Maximum Output DC15 V 3 34 A Maximum Ratin...

Page 21: ...table remove the rubber legs Distance between M6 screws 25 mm 50 mm Applicable screw Provided hexagon socket screw with washer M6 4 pcs Applicable tool Provided Allen wrench for M6 screw Distance betw...

Page 22: ...Approx 0 09 kg SZX2 COBH Oblique high contrast cartridge Oblique high contrast 35 mm 80 x 15 mm Approx 0 09 kg SZX2 COBL Oblique low contrast cartridge Oblique low contrast 35 mm 80 x 15 mm Approx 0...

Page 23: ...If the proper AC adapter and the power cord are not used the electric safety and the EMC Electromagnetic Compatibility performance of the product cannot be assured If no power cord is provided please...

Page 24: ...taching the illumination cartridge Optional Align the indicator C of the illumination cartridge you want to attach with the indicator D of the illumination cartridge mount and push in the illumination...

Page 25: ...kness of 0 1 mm can be inserted TIP 4 Attaching the photo sheet filter commercially available Cut the four corners of the photo sheet filter by approx 10 mm using the scissors In a same way as 1 on pa...

Page 26: ...of the base the extended part C of the focusing unit may interfere with the back side of the column mount of the base TIP NOTE 5 Attaching the focusing unit Optional Insert SZX2 AN Analyzer to the tip...

Page 27: ...iption Allen wrench for M4 screw Provided with SZX2 ILLTSA Hexagon socket screw M4 Provided with SZX2 ILLTSA Flip the base to its back and remove the front rubber legs 2 pcs A using the Allen wrench T...

Page 28: ...able As the rubber legs are not used the anti vibration effect with the rubber leg is lost Use the tools shown in the table below Tool Description Allen wrench for M4 screw Provided with SZX2 ILLTSA H...

Page 29: ...er for ILLT to the base 4 5 5 4 Place the base on the anti vibration table and loosen the screws E Align the bottom of the plate with the surface of the anti vibration table and secure the screws E 6...

Page 30: ...elow Tool Description Driver for stage glass frame Provided with the base Allen wrench for M4 screw Provided with SZX2 STADM Hexagon socket screw M4 Provided with SZX2 STADM SZX2 STADM is necessary fo...

Page 31: ...2 Place the protrusion H on the front side of the base and rotate the clamping screw I in clockwise direction to secure U SRG2 using the allen screwdriver provided with the microscope frame TIP 3 4 E...

Page 32: ...28 C 3 Attaching SZH SG Gliding stage or SZH SC Cup stage Place SZH SG D or SZH SC E on SZX2 STADM C 3 D E...

Page 33: ...buy locally the power supply cord which is approved by one of the agencies mentioned in Table 1 please use replacements approved by any other equivalent and authorized agencies in your country Countr...

Page 34: ...Cables BASEC BASEC HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 sterreichischer Verband f r Elektrotechnik VE VE HAR 30 10 50...

Page 35: ......

Page 36: ...to this product EVIDENT CORPORATION 6666 Inatomi Tatsuno machi Kamiina gun Nagano 399 0495 Japan Life science solutions Life science solutions Service Center Our Website https www olympus lifescience...

Reviews: