Maintenance
Do not perform any maintenance operation with the power on.
Clean the device with a soft damp cloth. Do not use any abrasive cleaning agents. Do not
immerse the device in water or any cleaning media.
Calibration
E2630-LEL detectors have been calibrated by the Manufacturer with standard gas mixtures
before delivery. Provided that the sensor is used under moderate conditions, field
recalibration is recommended every 12 months. Please contact your dealer for more
information.
Delivery set
●
Carbon Monoxide Detector E2630-LEL
●
Magnet key
●
Mounting accessories:
○
4 screws and 4 plastic dowel plug
Order code for E2630-LEL options
E2630 options
Order code
Integrated 90...265 V mains power supply module
E2630-LEL-230
Integrated 24 VAC power supply module
E2630-LEL-24VAC
15