PRESENT FAILURES
READING
When the “Failure” function is displayed, press the confirm
key “ ” to display the present failures.
If no failures are currently present, after pressing the
confirm key “ ” the message “End failures” will be dis-
played.
The monitored failures are:
Compressor
The machine is locked if the compressor runs non-stop for
more than 24 hours.
RAM Data
One or more areas of the RAM contain wrong data which
was corrected with the default values.
The machine will continue to function, but it would be
advisable to initialise as soon as possible.
Probe
The machine is locked after 5 minutes if the internal
temperature sensor is disconnected; the display will indi-
cate a temperature of -11° C.
The machine is locked after one hour if a sensor short
circuit is detected; in this case the display will indicate a
temperature of +41° C.
Motor errors
With this function the failed motors are displayed for
approximately 1 second.
Scrolling through all failed motors is automatic.
Note:
By restarting the machine any blocked motors are de-
tected as not present.
Dispensing compartment lock
When the function “unlock compartment with dispensing”
and the parameter “out of service if open” are active, the
machine will lock if the locking device of the dispensing
compartment remains blocked when closed or it does not
close within the programmed time.
Motors status
This function is used to read the last failure that occurred
in each spiral, even if the machine configuration has an
empty position.
A motor can be in una of the following conditions:
- motor functioning;
- motor not present; when the motor is not detected at
machine start-up.
- motor disconnected; when a motor detected at ma-
chine start-up is not detected during a selection.
- motor blocked; when the positioning button is not
operated within the “timeout”.
- empty spiral; when, with the dispensing control in-
stalled, no dispensed product is detected.
Note:
By restarting the machine any blocked motors are de-
tected as not present.
RESET
By confirming this function all current failures will be reset.
Summary of Contents for Snakky SL
Page 2: ......
Page 54: ...Sx36901...
Page 55: ...Snakky SL...
Page 57: ...SCHEMA ELETTRICO WIRING DIAGRAM MACCHINA MACHINE Snakky SL...
Page 58: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 59: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 60: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 61: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 62: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 64: ......