COOLING UNIT
The cooling unit is arranged at the bottom
of the cabinet and activated by the relay
placed in the electric panel.
The cool air from the cooling unit is dis-
pensed by the grid at the back of the box.
The machine is supplied with shutters that
can customise temperature stratification in
the box (max. 3 areas at various tempera-
tures).
The stratification level of the refrigerated
box temperature will vary according to the
number and position of shutters.
uNiform
tEmpEraturE
One single temperature in the whole box:
cool air distribution grid completely open.
stratifiED
tEmpEraturE
Maximum 3 areas at various temperatures
(0-4°C for “food” products, 5-8°C for food
drinks originally sealed, 8-16°C for snacks).
To change the temperature stratification
level, refer to the chapter about mainte-
nance.
tEmpEraturE
rEgulatioN
The refrigerated box temperature can be
set between 3.5°C (if the food management
is ON) or 5°C (if the food management is
OFF) and 20°C by means of a software pro-
gramme.
DEfrost
The cooling unit is automatically defrosted
every 6 hours.
The defrost time can be directly pro-
grammed by means of a software pro-
gramme.
FIRST POWER-ON
When you power on the machine for the
first time, the following will be checked be-
fore setting the equipment at work:
-check the number of trays you have actu-
ally connected with the machine
-softvend re-positioning (if available)
The following will appear in sequence on
the display:
-software release
-presence of the photocells intended to
detect the dispensing cycle
-number of trays you have actually con-
nected
-presence of the device intended to prevent
the dispensing compartment from opening
(if any)
-refrigerated box temperature measured by
the probe
You can programme the machine to display
the number of selections you have made for
some seconds (total vends).
The machine is set to the normal operation
mode after some seconds
Attention !!!
Wait for the steady-state temperature
to be reached (pull down up to 3 hours)
before inserting the products to be dis-
pensed.
The manufacturer disclaims all respon-
sibility for any damage caused by the
non-observance of the precaution men-
tioned above.
r
Efill
rEsEt
(
if
rEquirED
)
The “refill code” is a 4-digit code used to
reset the counters that manage the signal-
ling of "ending products".
Enter the “refill code” (1234 by default) to
reset the counters and set the machine to
the normal operation mode.
As an alternative, press key
�
to set the
machine to the normal operation mode
without resetting any counter.
After 1 minute, if no key is pressed, the ma-
chine will automatically switch to the normal
operation mode without resetting any coun-
ter.