background image

Oxford

®

Oxford Transaid 130

294000.10398  Rev A

WArNING

•  The oxford Transaid 10 is designed to facilitate the transfer procedure. Any other use is not permitted.

•  The oxford Transaid has a maximum safe working load of 10kg. Do NoT exceed the safe working load.

•  ALWAYS maintain a clean and tidy working environment.

•  ALWAYS plan the transfer operation before commencing.

•  ALWAYS carry out transfer operations according to the instructions in this user manual.

•  Do NoT push the oxford Transaid at speeds exceeding a slow walking pace.

•  The oxford Transaid 10 should be used by competent, trained personnel only.

•  The oxford Transaid 10 should be maintained and serviced at least once a year, by a competent person.

•  Should the oxford Transaid be damaged during normal use or in transit, the product must not be used.  

  please contact your local oxford distributor or Joerns Healthcare.

•  The patient should ALWAYS be seated during the transfer and the back support should be positioned   

  behind the patient.

•  The oxford Transaid should only be used on flat surfaces.

•  only approved genuine spares should be used when replacing parts.

•  Do NoT use the back support to lift the product when transporting or storing the device.

•  Do NoT park the oxford Transaid on any sloping surface, loaded or unloaded.

•  Do NoT manoeuvre the oxford Transaid down steps, loaded or unloaded.

•  When inserting the back support into the transfer position, care must be taken so as not to injure the patient.

•  Do NoT attempt to lift the Transaid whilst the patient is seated or standing in the unit.

Summary of Contents for Oxford Transaid 130

Page 1: ......

Page 2: ......

Page 3: ...n the following Carton contents General guidance for use and an overview of the product Step by step operating instructions Maintenance and inspection information Warranty information The Transaid 130...

Page 4: ...ned to assist with care duties for patients who have some difficulty walking but have the ability to stand independently Using this device assists the caregiver to be able to move the patient safely a...

Page 5: ...ce a year by a competent person Should the Oxford Transaid be damaged during normal use or in transit the product must not be used Please contact your local Oxford distributor or Joerns Healthcare The...

Page 6: ...ck support The Transaid has a detachable back support inside width 49 5cm It is designed to provide reassurance for the patient during the transfer and encourage them to sit in an upright position The...

Page 7: ...m user weight limit 130 kg Total height 1090 mm Overall width 730 mm Seat height clearance 640 mm Ground clearance 730 mm Turning radius 1050 mm Weight 21 4 kg Turning Circle Back Support Storage posi...

Page 8: ...in the storage position instruct the patient to place their feet centrally on top of the footplate Assist the patient if necessary Now apply the brakes on the rear castors Step 3 Ask the patient to le...

Page 9: ...rior to commencing transfer ensure the patient is holding onto either the back support or front grab rail Unlock the rear castors and transfer the patient to the desired location i e chair toilet bed...

Page 10: ...Transaid is clean Clean using a damp cloth with ordinary soap and water and or any hard surface disinfectant Harsh chemical cleaners or abrasives should be avoided as these may damage the surface fini...

Page 11: ...ct Person Tel Condition Good Satisfactory Poor Observations Good Sat Poor Findings Actions Hygiene of device Backrest black Seat support tubes Footplate retaining clips Seat Castors front rear Frame W...

Page 12: ...100070 3 Footplate 13100110 4 Seat support tubes 13300010 5 Braked rear castor 13100100 6 Front castor 13100260 7 Front castor pin 13100270 8 Cap d 30 13100200 9 Cap for seat support rail 13100200 10...

Page 13: ......

Page 14: ......