Evo Flex Series Manual 

Page 5 

4. Installation 

4.1 Transit 

When transporting the unit, ensure the unit is kept standing upright. Laying the unit down may damage internal parts. 

If the unit needs to be hung up (such as for lifting with a crane) use an 8 metre cable. Ensure there is some kind of 

padding between the cable and the unit to prevent damage to the heat pump cabinet. 

4.2 Location of Install 

The unit can be installed in any outdoor area which can carry the weight of heavy machinery, such as a terrace, 

rooftop, the ground etc. 

• 

The location must have adequate ventilation and be free from strong winds. 

• 

The installation location must be free from heat radiation and fire hazards. 

• 

Ensure there are no obstacles near the air inlet and outlet of the heat pump. 

• 

There must be a water channel around the heat pump to drain condensing water. 

• 

Ensure that there is enough space around the unit for maintenance. 

• 

The heat pump can be installed onto the concrete basement using expansion screws, or onto a steel frame 

with rubber feet which can be placed on the ground or rooftop. Ensure the unit is placed horizontally. 

4.3 Minimum Clearances 

A: 

500mm 

B: 

1500mm 

C: 

1000mm 

D: 

500mm

 

 

4.4 Plumbing 

  Try to reduce the resistance to the water from the piping. 

  The piping must be clear and free from dirt and blockage. A water leakage test must be carried out to ensure that 

there is no water leaking before the installation can be made. 

  The pipe must be tested by pressure separately. DO NOT test it together with the unit. 

  There must be an expansion tank on the top point of the water loop, and the water level inside the tank must be at 

least 0.5meters higher than the top point of the water loop. 

  The flow switch is installed inside of the heat pump, check to ensure that the wiring and action of the switch is 

normal and controlled by the controller. 

  Try to avoid any air from being trapped inside the water pipe, there must be an air vent on the top point of the 

water loop. 

  There must be a thermometer and pressure meter at the water inlet and outlet for easy inspection during running. 

  There must be drainage on the low points of the water system, and there is already drainage on the chassis of the 

heat pump. The water in the system must be drained out during winter if the heat pump is not to be used. 

 

4.5 Electrical Connection 

  Open the panel and open the power line hole 

  Thread the power line though the hole and connect it to the power line terminal. The three-core control line of the 

remote controller shall be plugged with the three-core signal line on the main board according to the wiring 

diagram. 

  For an external water pump, thread the power line of the water pump through the hole and connect it to the water 

pump terminals. 

  If an additional auxiliary heater is needed to be to be controlled by the heat pump controller, the relay (or power) of 

the aux-heather must be connected to the relevant output of the controller. 

Summary of Contents for Evo Flex

Page 1: ......

Page 2: ...h 7 5 2 3 Setting the Target Temperature 7 5 2 4 Fast Heating Mode 8 5 2 5 Setting a Timer 8 5 2 6 Setup Interface 8 5 2 7 Setting the Date Time 8 5 2 8 Fault Interface 8 5 2 9 Colour Display Calibration 8 6 Troubleshooting 9 6 1 Electronic Control Fault Table 9 6 2 Frequency Conversion Board Fault Table 10 6 3 Troubleshooting Table 11 7 Appendix 12 7 1 Parameter List 12 7 2 Install Sketch Map 12 ...

Page 3: ...apacity automatically and control the room temperature accurately TECHNICAL DATA Evo Flex 10 Evo Flex 17 Evo Flex 25 Heating Capacity Range kW 2 5 10 8 5 0 17 3 7 0 25 1 Heating Power Input Range kW 0 8 2 77 1 2 4 55 2 5 6 54 Cooling Capacity Range kW 2 0 10 0 5 0 14 5 7 0 20 0 Cooling Power Input Range kW 1 0 3 4 1 6 5 6 2 5 9 0 Frequency Hz 30 90 30 90 30 90 ErP Level 35 C A A A ErP Level 55 C A...

Page 4: ...eat com au Evo Flex Series Manual Page 3 2 Dimensions Evo Flex A L B W C H D E F G 10 980 465 910 700 445 338 132 Evo Flex A L B W C H D E F G H 17 990 437 1315 650 525 395 330 133 Evo Flex A L B W C H D E F G 25 1175 450 1588 725 400 320 254 ...

Page 5: ...or the rotating fan parts The unit must be handled and lifted with appropriate equipment in correlation with the unit s size and weight Electrical power must be switched off before any work is started on the unit Do not expose the unit to or install near any flammable gases Ensure there is a circuit breaker for this unit Copper and iron can not be used as a fuse The unit is equipped with an over l...

Page 6: ...rried out to ensure that there is no water leaking before the installation can be made The pipe must be tested by pressure separately DO NOT test it together with the unit There must be an expansion tank on the top point of the water loop and the water level inside the tank must be at least 0 5meters higher than the top point of the water loop The flow switch is installed inside of the heat pump c...

Page 7: ...n the controller to see if there is any failure indications The gas gauge can be connected to the check valve to see the high pressure or low pressure of the system during trial running Trial Operation Start the heat pump and check whether the water pump is running if it is running normally there will be 0 2MPa on the water pressure meter When the water pump runs for 1 minute the compressor will s...

Page 8: ...the unit is in defrosting mode When this icon is shown the unit is in hot water mode When this icon is shown the unit is in heating mode 5 2 Operating Functions 5 2 1 Start up Shutdown To turn the unit on or off press ON OFF button The icon will be grey when the unit is off and green when it is on 5 2 2 Mode Switch From the main menu there are five different operating modes that can be chosen from...

Page 9: ...tory interface CURVE View the temperature curves 5 2 7 Setting the Date Time From the Setup interface press CLOCK to enter into the system date time setting menu Use the arrows to adjust the date time as required then press the enter button to save changes Press the return key to return to the previous menu or to cancel any changes 5 2 8 Fault Interface Press the FAULT icon on the main menu to dis...

Page 10: ...ion E04 The compressor is overloaded Check whether the system of the compressor is running normally Communication Fault E08 Communication failure between wire controller and mainboard Check the wire connection between remote wire controller and main board HP Protection E11 The high pressure switch is broken Check the pressure switch and cold circuit LP Protection E12 Low pressure1 protection Check...

Page 11: ...n connection Communication Fault DSP F11 DSP and Inverter board communication failure Check the communication connection Communication Fault Inverter Board F12 Communication failure between inverter board and main board Check the wire connection between remote inverter board and main board IPM Overheat Stop F13 The IPM module has overheated Check and adjust the current measurement Weak Magnetism A...

Page 12: ...ystem Lack of gas Check the gas leakage and recharge freon Block on filter or capillary Replace filter or capillary Lack of water flow Clean the water filter and discharge the air in water loop Compressor do not run Power supply failure Check off the power supply Compressor contactor broken Replace compressor contractor Power cable loose Tighten the power cable Protection on compressor Check the c...

Page 13: ...Cap C If reducing the pressure of water supply unscrew the pressure to adjust the screw B If increasing the pressure of water supply screw down the pressure to adjust the screw B When the system needs to be filled with water at first rest the handle A of filled water Then the handle A can return close when the system is full of water Automatic filled water valve needs periodic cleaning When you mu...

Page 14: ... Nameplate maximum current Phase line Single Phase Phase Line Three Phase Earth line MCB Creepage Protector Signal Line No more than 10A 2 x 1 5mm2 3 x 1 5mm2 1 5mm2 20A 30mA less than 0 1 sec n x 0 5mm2 10 16A 2 x 2 5mm2 3 x 2 5mm2 2 5mm2 32A 16 25A 2 x 4mm2 3 x 4mm2 4mm2 40A 25 32A 2 x 6mm2 3 x 6mm2 6mm2 40A 32 40A 2 x 10mm2 3 x 10mm2 10mm2 63A 40 63A 2 x 16mm2 3 x 16mm2 16mm2 80A 63 75A 2 x 25m...

Page 15: ...AI02 Water output temperature input 19 AI03 System exhaust temperature input 20 AI04 Reserved 21 AI05 System suction temperature input 22 AI06 System coil temperature input 23 AI07 Ambient temperature input 24 AI08 Water tank temperature input 25 AI09 AI20 Reserved 26 AI21 Suction pressure input 27 AI22 Exhaust pressure input 28 DI01 System high pressure input 29 DI02 System low pressure input 30 ...

Page 16: ... should be dry clean and well ventilated Make sure there is nothing blocking the airflow of the heater e g Leaf litter Clean the heat exchanger every few months to keep a good heat exchange rate and save energy You should discharge the water at the bottom of the water pump if the unit will not be used for an extended period Discharge all water in the water pump and water system so that freezing of...

Page 17: ...lained within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b provide a copy of your receipt as proof of purchase c have completed the online Warranty Registration Form 5 Onsite technical service is available within t...