GUARANTEE

This product is guaranteed against defects in material and workmanship for 2 years 
from the date of purchase, under normal usage. The guarantee DOES NOT APPLY 
in case of improper use, negligence, lack of maintenance or accidental damage to 
the evoUV. If the evoUV fails due to a manufacturing fault within this period it will 
be either repaired or replaced free of charge. Liability is limited to replacement of 
the faulty product only; no other costs will be reimbursed. This guarantee is not 
transferable and does not affect your statutory rights. This guarantee does not confer 
any rights other than those expressly set out above. This guarantee does not cover 
the evoUV bulb or quartz sleeve.

The manufacturer or supplier shall not be responsible, or held liable for any 
damages caused by defective components or materials of this product; or for loss 
incurred by interruption of service; or any consequential/incidental damages and 
expenses arising from the production, sale use or misuse of this product or any other 
consequential loss.

IMPORTANT: 

Please keep your proof of purchase (sales receipt) safe for the 

duration of the warranty period, as this will be needed in the event of a  
warranty claim.

Evolution Aqua and its dealers shall not be held liable for any loss of fish, plants or 
any other livestock as a result of any failure or defect of this product. 

The installation and use of your product outside of our recommendations as printed 
in this manual may also void the warranty.

18

Summary of Contents for evoUV

Page 1: ...ttempt to conduct any type of maintenance on the evoUV Ensure the unit is installed in the recommended orientation Fit the quartz sleeves and O rings and switch on pump to check that unit is water tig...

Page 2: ...e an appliance for anything other than its intended use The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition This unit must be earthed when earth...

Page 3: ...sleeve are packed separately for safe transit Please refer to pages 6 and 7 of this manual for instructions on how to install the bulb and quartz sleeve Quartz Sleeve O Rings and End Cap Sealing Ring...

Page 4: ...S AND COMPONENTS LIST Please familiarise yourself with the components shown in the diagram below For optimum performance the electronic ballast has been configured for UV bulbs supplied by Evolution A...

Page 5: ...pipework not supplied For best possible sterilisation results use an over rated unit with an under rated flow rate and replace the UV bulb with new every six months Always combine with effective mech...

Page 6: ...wards the thread on the UV body ensuring that equal amounts of quartz sleeve are visible at each end of the unit 7 Fit the quartz sleeve O Ring G at the other end of the quartz sleeve again ensuring t...

Page 7: ...e evoUV units are sealed in a water tight unit The evoUV has an IP rating of 64 Fix your evoUV into position using the stainless steel brackets attached to the evoUV Screws and washers are not provide...

Page 8: ...return to main aquarium using hard pipe evoUV connected to external filter Fit evoUV to outlet return hose to aquarium evoUV connected to pump in sump Fit evoUV to pump return to main aquarium using f...

Page 9: ...ightened using tools as it may crack or damage the thread Slide flexible pvc hose not supplied over the barb of the hosetail at each end This can be eased by dipping the end of the flexible pvc hose i...

Page 10: ...Turn on pump and pump water through unit STEP 5 Check locking nuts for signs of water leaking STEP 7 If no water leaks quartz sleeve has been properly installed Proceed to connection to the electrici...

Page 11: ...lift the evoUV as this may cause damage WARNING A Residual Current Device RCD also known as the Residual Current Circuit Breaker RCCB with a tripping current not exceeding 30mA must be installed in th...

Page 12: ...e UV bulb pins You may need to hold the other end of the UV bulb to help you fit the socket 6 Ensure the UV bulb socket is firmly connected to the UV bulb 7 Repeat steps 3 to 6 at the other end of the...

Page 13: ...s out of the way carefully slide out the UV bulb WARNING If the end caps electrical connections get wet during this procedure please ensure that they are thoroughly dried before re connecting TO INSTA...

Page 14: ...water 7 Clean the sleeve and polish with a soft cloth or paper towel If you live in a hard water area you may get limescale on the quartz sleeve this can be easily removed by using vinegar or a cold...

Page 15: ...the end caps Please see the troubleshooting section Thermal Overload Protection This will automatically switch off the unit should the temperature exceed the maximum operating temperature limits Auto...

Page 16: ...age caused by improper fitting of the quartz sleeve o rings and locking nuts are not covered under warranty Since fitting the evoUV my pump flow is restricted In order to be an effective steriliser th...

Page 17: ...ogens and helping to prevent the spread of pathogens from tank to tank on centralised fish systems if set up correctly It can only ever be effective on pathogens which pass inside the unit and are dir...

Page 18: ...rantee does not cover the evoUV bulb or quartz sleeve The manufacturer or supplier shall not be responsible or held liable for any damages caused by defective components or materials of this product o...

Page 19: ...19...

Page 20: ...s manufacturer who put innovation research and development at the top of their agenda With a proven track record for delivering the latest technology to the aquatics and fish farming markets we are th...

Reviews: