CLEANING WITH THE NEXUS AUTOMATIC SYSTEM
MANUAL CLEAN
When you push the “MANUAL CLEAN” button a cleaning cycle will begin.
Once initiated, we advise that you allow the cleaning cycle to run from start to finish. However, in unexpected
circumstances by interrupting and restarting the power supply, the system will reset itself to a zero start condition
for all functions i.e.; inlet valve open, automated waste valve closed, timer at start, once the power is resumed.
(A power cut will have the same effect).
AUTOMATIC CLEAN
You do not need to push any buttons to start an Automatic Clean.
The frequency of cleaning is factory set to cycle once every three days.
This time period can be easily adjusted by changing the CYCLE TIMER located inside the control box.
Once an Automatic Clean is initiated, we advise that you allow the cleaning cycle to run from start to finish. However,
in unexpected circumstances by interrupting and restarting the power supply, the system will reset itself to a zero start
condition for all functions ie; inlet valve open, automated waste valve closed, timer at start, once the power is resumed.
(A power cut will have the same effect).
SCREW A
SCREW B
DO NOT
ADJUST
(Covered
by label)
THE CYCLE TIMER EXPLAINED
THE CYCLE TIMER
INSIDE THE CONTROL BOX
24