Operating Advice

Always clamp the work piece on a rigid support such as a 
bench or saw horses where possible. This tool is equipped 
with a safety start feature – to start the tool, you must 
first push in the switch on the side of the handle with your 
thumb – you can then depress the main trigger switch to 
power the motor. Do not force the tool – let the speed of 
the saw blade do the work. Cutting performance will not 
improve by applying more pressure on the tool and blade 
life will be reduced. When using the parallel guide, ensure 
that it is parallel with the blade and not the base of the tool, 
as otherwise the blade and motor could become damaged. 
To set the guide, loosen the two retaining screws, and slide 
it up snugly against the side of the work piece. Retighten 
the screws to secure it in the desired position. Place front 
edge of saw squarely on work before starting motor. When 
starting a cut, sight the cutting line with the line of cut guide 
taking care to introduce the blade to the material slowly, so 
as not to damage its teeth. Use both hands to move the saw 
forward through the work piece.

Laser Sight Guide System

An additional feature of this machine is the laser sight system, 
which is intended as a guide only and should not be relied upon 
for the accuracy of a cut. Remove the battery compartment 
cover and fit the supplied batteries, taking care to observe the 
correct polarity, then replace the cover. Press the switch to 
the on position to activate, and remember to turn off the laser 
when you have finished a cut. Before use the sight must be 
aligned by means of the adjustment screw. Important Notice: 
Do not point the laser at anyone and NEVER look into the laser 
light, as serious eye damage may occur.

Chip Collection

This tool is provided with a chip collector compartment. 
When the chips accumulate up to the see-through window, 
remove the cover, clean out the cover, then replace it, and 
tighten the knobs. Notice: The metal chips inside the cover 
may be very hot and sharp - do not touch with bare hands.

Ear and eye protection MUST be worn while operating this
equipment. Do NOT touch the blade while it is in motion. 

Always follow the Personal Protection Equipment (PPE) 
recommendations while operating this tool. This machine is 
designed for cutting steel using the appropriate TCT (Tungsten 
Carbide Tipped) blades and accessories. It should NOT be 
modified and / or used for any application other than for which 
it was intended, including powering other equipment. 

Ensure that the total work area can be viewed from the 
operating position. Use barriers to keep people away. Do 
not operate the tool in explosive environments – power tools 
create sparks that may ignite flammable materials or gases. 

Do not operate the tool in damp or wet conditions, as electric 
shocks may result. Always use both hands to operate the 
tool. Always ensure that the material you are working on is 
securely clamped.

• This tool is equipped with an approved cord and plug for its 
intended Country of use.
•  Remove  plug  from  power  supply  before  replacement  of 
the blade, making adjustments or other maintenance work.
• Use only genuine EVOLUTION brand saw blades.
• Inspect the machine and blade before each use and do not 
use deformed, cracked, worn or otherwise damaged blades.
• Ensure the blade is correctly mounted and is appropriate 
for the material to be cut.
• Do not use blades made of high-speed steel.
• Do not use blades that do not comply with the characteristics 
specified in these instructions.
• Do not stop the blade by lateral pressure on the disc.
• Ensure that moveable guards operate freely without jamming.
• Never use the tool without the original protection guard system.
Do not lock the moving guard in the open position.
• Always keep the power cord away from moving parts of the tool.
• When you put the tool away, switch off the motor and ensure 
that all moving parts have come to a complete standstill.
• In case of jamming, immediately switch off the tool and 
disconnect the plug.
• Before using accessories, always compare the maximum 
allowed RPM of the accessory with the RPM of the tool.
•  Ensure  that  the  cutting  depth  adjustment  handle,  angle 
adjustment  handle,  and  side  handle  are  firmly  fixed  whilst 
using the tool (fig. 1).
• Only use the flanges and washers that are supplied with the 
tool, and replace them if they become damaged or scored.

Adjustment Of The Cutting Depth

Release the handle to adjust to the required cutting depth. 
Ensure that the blade protrudes a maximum of 3/16” (4mm) 
through the material being cut. Tighten the handle to lock in 
position. Note: The safety guard (fig. 1) is marked in increments 
from 0 – 84mm to assist in setting the depth of cut.

Adjustment Of The Cutting Angle

Release both locking handles (fig. 2) and adjust to the required 
cutting angle by lining up the mark with the printed scale. Tighten 
both handles to lock in position. Note: There are certain compound 
cuts on which it may be necessary to manually retract the guard 
to allow the blade to enter into and / or through the cut.

Line Of Cut Guide Slots

Guide slots are provided at the front of the saw base. The left slot 
is used to follow a line when making a 90-degree cut. The right 
slot is used to follow a line when making a 45-degree cut.

Summary of Contents for EVO230-HDX

Page 1: ...www evolutionsteel com 230mm 9 TCT Steel Cutting Circular Saw Instruction Manual Read instructions before operating this tool...

Page 2: ...Hazardous Substances in electrical electronic equipment RoHS EU Directive 2002 95 EC restricts the use of the 6 substances below in the manufacture of specific types of electrical equipment Whilst thi...

Page 3: ...al representations of fitness or to waive any of the foregoing terms of sale and none shall be binding on Evolution Power Tools Questions relating to this limited warranty should be directed to the co...

Page 4: ...he rate for which it was designed b Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired c Dis...

Page 5: ...dle or motor housing If both hands are holding the saw they cannot be cut by the blade b Do not reach underneath the workpiece The guard cannot protect you from the blade below the workpiece c Adjust...

Page 6: ...sag under their own weight Supports must be placed under the panel on both sides near the line of cut and near the edge of the panel e Do not use dull or damaged blades Unsharpened or improperly set...

Page 7: ...automatically Mounting Removing TCT Saw Blades Remove the chip collection cover from the machine by undoing the hexagonal screw Loosen the screw that retains the spanner to the machine and remove the...

Page 8: ...that the total work area can be viewed from the operating position Use barriers to keep people away Do not operate the tool in explosive environments power tools create sparks that may ignite flammab...

Page 9: ...st SERVICE CENTER or Evolution Power Tools USA Iowa if in the USA All repairs and servicing made by these centers are fully guaranteed against defective materials and workmanship 40T 9 230mm TCT Wood...

Page 10: ...www evolutionsteel com 10 EVO230 HDX CUTTING THROUGH 1 2 MILD STEEL PLATE...

Page 11: ...www evolutionsteel com 11 EVO230 HDX TRIGGER SWITCH EVO230 HDX FIGURE 1 EVO230 HDX 1750W MOTOR EVO230 HDX FIGURE 3 EVO230 HDX TILTING BLADE EVO230 HDX FIGURE 2...

Reviews: