18
www.evolutionfury.com
Forwards and backwards adjustment of the rip fence
is possible. Loosen the two finger nuts and slide the
aluminium extrusion to the desired position. Tighten the
finger nuts securely.
Note
We recommend that normally the rip fence be adjusted so
that the rear of the guide is level with the rear of the blade
where it emerges from the table. See Fig 21.
Note
If the rip fence is used on the LH side of the blade the
aluminium extrusion will have to be repositioned to the RH
side of the steel box-section carrier.
Undo the two wing nuts and remove the aluminium extrusion
with its bolts in place. Reposition the extrusion on the RH side
of the steel carrier and re-attach the wing nuts. See Fig 22.
Adjust as above.
Remember to return to the original configuration when the rip
fence is in the normal (RH) operating position.
5. Mitre Gauge
The mitre gauge can be used on either side of the table and
runs in two inverted T slots in the table top.
Turn the vertical handle counter-clockwise to unlock the mitre
gauge, and adjust to the required angle. Turn the handle clockwise
to lock the mitre gauge at the chosen angle. See Fig 23.
Note
The extruded aluminium face plate of the mitre gauge should
be adjusted so that it is close to, but does not foul the blade
guard. Adjust by loosening the two wing nuts and sliding the
faceplate to the required position. Securely tighten the wing
nuts.
Fig 21
Close up view of the rip
fence guide.
Fig 22
Close up view of the
rip fence set up for LH
operation.
Fig 23
Close up view of the mitre
gauge set to an angle.