TECHNICAL REFERENCE MANUAL
Dyvi 2.0.7.2
Processing Module Installation and Cabling
37
Network Cabling Examples
One Single Processing Module (Topology: none)
In this topology the 100 GigE connectors are not used at all.
Two Processing Modules, stacked local (Topology: Direct-2)
In the topology
Direct-2
, two Processing Modules are connected with
one
QSFP28 to QSFP28 cable.
There is one link between the two
A
ports.
Depending on the required cable length, it could be a Twinax passive
cable or a QSFP28 optical module solution.
Figure: Direct-2 cabling scheme
Figure: QSFP28 Twinax cable
Three Processing Modules, stacked local (Topology: Direct-3)
In the topology
Direct-3
, three Processing Modules are connected with
three QSFP28 to QSFP28 cables.
The cabling depends on the Processing Modules Device-IDs and must
match exactly as outlined in the drawing.
Depending on the required cable length, it could be a Twinax passive
cable or a QSFP28 optical module solution.
Summary of Contents for DYVI
Page 1: ...HARDWARE TECHNICAL REFERENCE MANUAL Version 2 0 7 2 September 2021 ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ......
Page 56: ...EVS Broadcast Equipment SA Issue 2 0 7 2 September 2021 46 GUI Installation and Configuration ...
Page 101: ......
Page 102: ......