6.6.
RAID Controller Boards
6.6.1.
RSAS Board on SAS Disk Array
Disk Arrays on systems with H3X boards have a controller on the disk array board.
Different configurations can be used
•
One internal array with a series of 6 disks
•
One internal array with two stacked series of 6 disks,
•
No internal storage
LEDs on Internal Array
LEDs 1 to 6 are used in case of one internal array of 6 disks.
LEDs 7 to 12 are used for the upper series of disks in case of one internal array of 2x6
disks.
LEDs correspond to the disks as schematized as followed:
upper
7
12
lower
1
6
upper
8
9
10 11
lower
2
3
4
5
LED
Status
Function
Disk
LEDs
Off
the corresponding disk is not started (not spinning)
On, fast blinking
(green)
the corresponding disk is starting (spinning)
On, steady (green)
the corresponding disk is started and used in the RAID
array
On, slowly blinking
(green)
the corresponding disk is started but not used in the
RAID array
STS
On (green)
the RSAS RAID controller is properly booted.
ERR
On (red)
errors occur during the data transfer between the RAID
controller and the disks
HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12.05
6. Boards Description
107
Summary of Contents for XT-3
Page 1: ...HARDWARE TECHNICAL REFERENCE MANUAL Version 12 05 November 2014 ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ......
Page 101: ...HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 6 Boards Description 91 ...
Page 122: ...Illustration 112 6 Boards Description EVS Broadcast Equipment SA Issue 12 05 C November 2014 ...
Page 125: ......