Electronic cylinder
Technology & media
The e-primo cylinder is available in versions for iButton or
RFID MIFARE technology. User keys are therefore designed
differently, depending on the technology.
At least one programming key and one user key are
required to operate one or more e-primo cylinders.
Media functions
Programming key | PK (Programming Key)
The programming key is used to start and stop the
programming procedure on the e-primo cylinder. It is also
used to limit the INIT button‘s function to the owner of
the programming key as well as to terminate the blocking
and emergency opening functions. A single programming
key can be used for multiple e-primo cylinders.
User key | UK (User Key)
The user key serves to lock and unlock the door, it is issued
to the user. The user key can also be trained for additional
functions, e.g. the ofice function.
Delete key | DK (Delete Key)
The delete key is used in programming mode to delete
validation of a lost programming or user key from the
e-primo cylinder‘s memory.
Copy key | CK (Copy Key)
The copy key is used in programming mode to start the
copy process in which the data of a programming or user
key is stored onto a delete key.
Ofice key | OK (Ofice Key) (available option)
The ofice key is used to train the user keys to the ofice
function as well as to enable the ofice function globally
on an e-primo cylinder. The ofice function permits con
-
tinuous release of the e-primo cylinder (e.g. during ofice
hours).
Blocking key | BK (Blocking Key) (available option)
The blocking key sets the e-primo cylinder into a continu-
ous locked condition; it cannot be activated from outside.
This function can only be terminated by the programming
key or the emergency opening key. A single blocking key
can be assigned to multiple e-primo cylinders but only one
blocking key per e-primo cylinder is possible.
Emergency opening key | EK (Emergency Key)
(available option)
The emergency opening key sets the e-primo cylinder to
its emergency opening function (continuously open). This
function can only be terminated by the programming key
or the blocking key. A single emergency opening key can
be assigned to multiple e-primo cylinders but only one
emergency opening key per e-primo cylinder is possible.
Summary of Contents for e-primo
Page 2: ...RFID MIFARE iButton 1 2 5 3 6 8 9 7 4 10 12 11 13 ...
Page 7: ...Deutsch 9 1 2 3 4 ...
Page 9: ...Deutsch 11 1 3 4 5 2 ...
Page 21: ...English 23 1 2 3 4 ...
Page 23: ...English 25 1 3 4 5 2 ...
Page 35: ...Français 37 1 2 3 4 ...
Page 37: ...Français 39 1 3 4 5 2 ...
Page 49: ...51 italiano 1 2 3 4 ...
Page 51: ...53 italiano 1 3 4 5 2 ...
Page 63: ...65 Español 1 2 3 4 ...
Page 65: ...67 Español 1 3 4 5 2 ...
Page 77: ...Nederlands 79 1 2 3 4 ...
Page 79: ...Nederlands 81 1 3 4 5 2 ...