14
KPM.X.Systemhandbuch_X3.0.EN.V1.9 | 05/2019 | Subjects to misprints and technical changes.
Xesar access component interface
All Xesar access components feature a plug-interface to update components via a tablet. The inter-
face may also be used as an emergency power supply for battery-operated Xesar access compo-
nents.
The interface is located on the front of all Xesar access components, behind the connector cover
(EVVA logo). Slightly press towards the inside on the left-hand side of the EVVA logo (near the "E")
with your finger and fold out on the right-hand side (near the "A") to access the interface.
After having used the interface, once again carefully close the connector cover (EVVA logo) to
protect the Xesar access components from penetrating dust and humidity.
Do not use pointed objects to open and close the cover to prevent potential
damage.
2.1.1
Xesar escutcheon
Figure 3: Xesar escutcheon (sample image)
The Xesar escutcheon is a battery-operated access component suitable for indoor and outdoor use.
The Xesar escutcheon is suitable for conventional metal frames and solid door locks with a handle
angle of up to 40°, for self-locking escape door locks as per EN 179/EN 1125, fire protection doors
and there are also versions available for panic and emergency exit doors with bar handles or push
handles as per EN 1125.
Please use the dedicated seal enclosed with the product in the event of a use outdoors or in zones
that are exposed to water.
Please check carefully to make sure the Xesar product you selected is suitable for your application.